c/kWh
Energy rating (cooling)
2.5
Heating: 1.5
Annual electricity use
6,606 kWh
912 cooling + 5,694 heating
Estimated running cost
$2,180 / year
$182 / month Β· $21,800 over 10 years
Capacity
14 kW cooling
14 kW heating

About the same electricity as the median of 19 comparable 14 kW reverse cycle multi-split / vrf registrations (6,606 kWh a year) in the cold zone. Uses less than 47% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 27% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Mitsubishi Heavy Industries FDC140KXZEN1-W running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 6,606$2,180$21,800
Mixed zone 3,539$1,168$11,679
Hot zone 4,346$1,434$14,342

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 14 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RSUYA5AVM16 kW heating14 kW cooling4,941 kWh/yr3$1,631
Panasonic U-5LZ2E516 kW heating14 kW cooling5,357 kWh/yr2.5$1,768
Panasonic U-5LZ2E816 kW heating14 kW cooling5,357 kWh/yr2.5$1,768
Mitsubishi Electric PUMY-SP112YKMD3-A14 kW heating12.5 kW cooling5,590 kWh/yr2.5$1,845
Mitsubishi Electric PUMY-SP112YKMD3-A Series14 kW heating12.5 kW cooling5,590 kWh/yr2.5$1,845

Heat pumps similar to the Mitsubishi Heavy Industries FDC140KXZEN1-W

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Panasonic U-5LZ2E816 kW heating14 kW cooling5,357 kWh/yr2.5$1,768
Daikin RSUYA5AVM16 kW heating14 kW cooling4,941 kWh/yr3$1,631
Mitsubishi Electric PUMY-SP125YKMD3-A-BS16 kW heating14 kW cooling6,470 kWh/yr2.5$2,135
Panasonic U-5LZ2E516 kW heating14 kW cooling5,357 kWh/yr2.5$1,768
Mitsubishi Electric PUMY-SP125YKMD3-A Series16 kW heating14 kW cooling6,470 kWh/yr2.5$2,135
Braemar MCMX140D108B16 kW heating14 kW cooling8,576 kWh/yr1.5$2,830

Other Mitsubishi Heavy Industries models of similar capacity

ModelStarsEst. cost / yrCompare
Mitsubishi Heavy Industries FDC140KXZEN114 kW heating14 kW cooling6,366 kWh/yr2$2,101
Mitsubishi Heavy Industries FDC140KXZES114 kW heating14 kW cooling6,331 kWh/yr2$2,089

Compare FDC140KXZEN1-W with another model

Mitsubishi Heavy Industries FDC140KXZEN1-W specifications

Type
Reverse cycle
Configuration
Multi-split / VRF
Air distribution
Ducted or non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
14.00 kW
Cooling power input
4.16 kW
Rated heating capacity (7 Β°C)
14.00 kW
Heating power input
3.68 kW
EER, full load (tested)
3.32
COP, full load (tested)
3.97
Rated AEER
3.29
Rated ACOP
3.70
Standby power (PIA)
29.2 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
69 dB(A)
Demand response (AS/NZS 4755)
No
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Mitsubishi Heavy Industries FDC140KXZEN1-W zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,9121,894
Coldresidential2.51.59125,694
Mixedcommercial––2,400971
Mixedresidential2.02.01,4122,127
Hotcommercial––5,296240
Hotresidential3.02.53,986360
Part-load test points (16 values)
h__h2_ext_cap_power_rated
3670 W
c__t1_half_cap_power_rated
1470 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1580 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
10800 W
h__h1_half_cap_heat_cap_rated
7000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
7000 W
c__low_temp_have_half_cap_results
No

New Zealand E3 registration details

Registration number
AAC10244
GEMS registration id
179264
Status
approved, available (self-reported)
Registration expires
16 June 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 20

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: mhiaa.com.au. How the derived figures are calculated.