c/kWh
Energy rating (cooling)
2.5
Heating: 1.5
Annual electricity use
20,055 kWh
2,597 cooling + 17,458 heating
Estimated running cost
$6,618 / year
$552 / month Β· $66,182 over 10 years
Capacity
40 kW cooling
40 kW heating

6% less electricity than the median of 18 comparable 40 kW reverse cycle multi-split / vrf registrations (21,358 kWh a year) in the cold zone. Uses less than 61% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 7% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Mitsubishi Heavy Industries FDC400KXZRE2 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 20,055$6,618$66,182
Mixed zone 10,236$3,378$33,779
Hot zone 12,507$4,127$41,273

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 40 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Toshiba MMY-MUP14S1HT8P-A40 kW heating40 kW cooling2,476 kWh/yr2.5$817
Mitsubishi Electric PUHY-M350YXM-A-BS40 kW heating40 kW cooling3,340 kWh/yr1.5$1,102
Mitsubishi Electric PUHY-M350YXM series40 kW heating40 kW cooling3,340 kWh/yr1.5$1,102
Panasonic U-14MF3R745 kW heating40 kW cooling17,008 kWh/yr3$5,613
Hitachi RAS-140HNCELW45 kW heating40 kW cooling18,609 kWh/yr2.5$6,141

Heat pumps similar to the Mitsubishi Heavy Industries FDC400KXZRE2

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Toshiba MMY-MUP14S1HT8P-A40 kW heating40 kW cooling2,476 kWh/yr2.5$817
Panasonic U-14MF3R745 kW heating40 kW cooling17,008 kWh/yr3$5,613
Toshiba MMY-MUP1401FT8P-A40 kW heating40 kW cooling21,195 kWh/yr3.5$6,994
Hitachi RAS-140RNCBLW45 kW heating40 kW cooling20,084 kWh/yr1.5$6,628
Daikin REYA14AYM45 kW heating40 kW cooling21,929 kWh/yr2.5$7,237
Mitsubishi Electric PUHY-M350YXM-A-BS40 kW heating40 kW cooling3,340 kWh/yr1.5$1,102
Hitachi RAS-140HNCELW45 kW heating40 kW cooling18,609 kWh/yr2.5$6,141
Mitsubishi Electric PUHY-M350YXM series40 kW heating40 kW cooling3,340 kWh/yr1.5$1,102

Compare FDC400KXZRE2 with another model

Mitsubishi Heavy Industries FDC400KXZRE2 specifications

Type
Reverse cycle
Configuration
Multi-split / VRF
Air distribution
Ducted or non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
40.00 kW
Cooling power input
12.02 kW
Rated heating capacity (7 Β°C)
40.00 kW
Heating power input
10.22 kW
EER, full load (tested)
3.23
COP, full load (tested)
3.71
Rated AEER
3.28
Rated ACOP
3.84
Standby power (PIA)
54.9 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
No
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Mitsubishi Heavy Industries FDC400KXZRE2 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––5,5895,398
Coldresidential2.51.52,59717,458
Mixedcommercial––7,0252,590
Mixedresidential2.52.04,0436,193
Hotcommercial––15,566565
Hotresidential2.53.011,645862
Part-load test points (16 values)
h__h2_ext_cap_power_rated
10100 W
c__t1_half_cap_power_rated
4400 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
3900 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
28000 W
h__h1_half_cap_heat_cap_rated
19600 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
20000 W
c__low_temp_have_half_cap_results
No

New Zealand E3 registration details

Registration number
AAC10475
GEMS registration id
182052
Status
approved, available (self-reported)
Registration expires
14 November 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 21

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 26 September 2026; last checked 27 September 2026. Manufacturer: mhiaa.com.au. How the derived figures are calculated.