c/kWh
Energy rating (cooling)
3
Heating: 2.5
Annual electricity use
17,008 kWh
2,241 cooling + 14,767 heating
Estimated running cost
$5,613 / year
$468 / month Β· $56,126 over 10 years
Capacity
40 kW cooling
45 kW heating

20% less electricity than the median of 18 comparable 40 kW reverse cycle multi-split / vrf registrations (21,358 kWh a year) in the cold zone. Uses less than 78% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 8% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Panasonic U-14MF3R7 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 17,008$5,613$56,126
Mixed zone 8,732$2,882$28,816
Hot zone 10,563$3,486$34,858

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 40 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Toshiba MMY-MUP14S1HT8P-A40 kW heating40 kW cooling2,476 kWh/yr2.5$817
Mitsubishi Electric PUHY-M350YXM-A40 kW heating40 kW cooling3,340 kWh/yr1.5$1,102
Mitsubishi Electric PUHY-M350YXM-A-BS40 kW heating40 kW cooling3,340 kWh/yr1.5$1,102

Heat pumps similar to the Panasonic U-14MF3R7

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Mitsubishi Heavy Industries FDC400KXZRE240 kW heating40 kW cooling20,055 kWh/yr2.5$6,618
Hitachi RAS-140HNCELW45 kW heating40 kW cooling18,609 kWh/yr2.5$6,141
Mitsubishi Electric PUHY-M350YXM series40 kW heating40 kW cooling3,340 kWh/yr1.5$1,102
Toshiba MMY-MUP14S1HT8P-A40 kW heating40 kW cooling2,476 kWh/yr2.5$817
Toshiba MMY-MUP1401FT8P-A40 kW heating40 kW cooling21,195 kWh/yr3.5$6,994
Hitachi RAS-140RNCBLW45 kW heating40 kW cooling20,084 kWh/yr1.5$6,628
Mitsubishi Heavy Industries FDC400KXZE245 kW heating40 kW cooling18,736 kWh/yr3$6,183
Mitsubishi Electric PUHY-M350YXM-A-BS40 kW heating40 kW cooling3,340 kWh/yr1.5$1,102

Compare U-14MF3R7 with another model

Panasonic U-14MF3R7 specifications

Type
Reverse cycle
Configuration
Multi-split / VRF
Air distribution
Ducted or non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
40.00 kW
Cooling power input
10.80 kW
Rated heating capacity (7 Β°C)
45.00 kW
Heating power input
10.70 kW
EER, full load (tested)
3.52
COP, full load (tested)
4.04
Rated AEER
3.60
Rated ACOP
4.09
Standby power (PIA)
91.0 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
80.4 dB(A)
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Country of manufacture
Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-14MF3R7 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––4,5434,586
Coldresidential3.02.52,24114,767
Mixedcommercial––5,7392,328
Mixedresidential3.03.03,4905,242
Hotcommercial––12,732591
Hotresidential3.54.09,685878
Part-load test points (19 values)
h__h2_ext_cap_power_rated
13800 W
c__t1_half_cap_power_rated
3370 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
3540 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
38400 W
h__h1_half_cap_heat_cap_rated
22500 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
9871.2 W
c__low_temp_half_cap_power_rated
3080.1800000000003 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
20000 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
43080 W
c__low_temp_half_cap_cooling_cap_rated
21540 W

New Zealand E3 registration details

Registration number
AAC7668
GEMS registration id
155661
Status
approved, available (self-reported)
Registration expires
2 August 2028
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 21

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.