c/kWh
Energy rating (cooling)
3
Heating: 1.5
Annual electricity use
3,102 kWh
336 cooling + 2,766 heating
Estimated running cost
$1,024 / year
$85 / month Β· $10,237 over 10 years
Capacity
5.6 kW cooling
7 kW heating

12% more electricity than the median of 25 comparable 6 kW reverse cycle ducted split system registrations (2,771 kWh a year) in the cold zone. Uses less than 32% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 60% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Panasonic CU-Z60UBRA running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,102$1,024$10,237
Mixed zone 1,528$504$5,042
Hot zone 1,689$557$5,574

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 5.6 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RZAV50CV1 / FBA50BAVMA6 kW heating5 kW cooling789 kWh/yr0$260
Toshiba RAV-GP561ATP-A1/RAV-GM561DTP-A15.6 kW heating5 kW cooling2,032 kWh/yr3$671
Panasonic U-60PZ3R5 / S-6071PF3E5.7 kW heating5.7 kW cooling2,135 kWh/yr3$705
Gree GUD50W1/NhC-S / GUD50PHS1/C-S5.8 kW heating5.3 kW cooling2,138 kWh/yr3.5$706
Panasonic U-60PZ4R5 / S-6071PF3E5.7 kW heating5.7 kW cooling2,172 kWh/yr3$717

Heat pumps similar to the Panasonic CU-Z60UBRA

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Carrier 38QSM060D8S/42QSM060D8S6.5 kW heating5.8 kW cooling2,518 kWh/yr3.5$831
Gree GUD50W1/NhC-S / GUD50PHS1/C-S5.8 kW heating5.3 kW cooling2,138 kWh/yr3.5$706
Carrier 38QSM053D8S/42QSM053D8S5.7 kW heating5.3 kW cooling2,338 kWh/yr3.5$772
Fujitsu AOTG18LACC/ARTG18LLTA6 kW heating5.2 kW cooling2,536 kWh/yr2.5$837
Samsung Electronics AC052TXAPKG/SA / AC052TNHDKG/SA6 kW heating5.2 kW cooling2,500 kWh/yr2.5$825
Daikin RZAC60GBV1 / FDYBA60AV17 kW heating6 kW cooling2,674 kWh/yr2.5$882

Other Panasonic models of similar capacity

ModelStarsEst. cost / yrCompare
Panasonic U-60PZ4R5 / S-6071PF3E5.7 kW heating5.7 kW cooling2,172 kWh/yr3$717
Panasonic U-60PZ3R5 / S-6071PF3E5.7 kW heating5.7 kW cooling2,135 kWh/yr3$705

Compare CU-Z60UBRA / CS-Z60UD3RAW with another model

Panasonic CU-Z60UBRA specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
5.60 kW
Cooling power input
1.70 kW
Rated heating capacity (7 Β°C)
7.00 kW
Heating power input
2.16 kW
EER, full load (tested)
3.33
COP, full load (tested)
3.15
Rated AEER
3.26
Rated ACOP
3.21
Standby power (PIA)
5.2 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic CU-Z60UBRA zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––723883
Coldresidential3.01.53362,766
Mixedcommercial––917431
Mixedresidential2.52.0532996
Hotcommercial––2,05991
Hotresidential3.03.01,547142
Part-load test points (20 values)
h__h2_ext_cap_power_rated
1900 W
c__t1_half_cap_power_rated
565 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
700 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
5400 W
h__h1_half_cap_heat_cap_rated
3500 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
1553.8 W
c__low_temp_half_cap_power_rated
516.41 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
2800 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
6031.2 W
c__low_temp_half_cap_cooling_cap_rated
3015.6 W

New Zealand E3 registration details

Registration number
AAC7348
GEMS registration id
152160
Status
approved, available (self-reported)
Registration expires
12 March 2028
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 10

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: papamy.panasonic.com.my. How the derived figures are calculated.