c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
3,422 kWh
403 cooling + 3,019 heating
Estimated running cost
$1,129 / year
$94 / month Β· $11,293 over 10 years
Capacity
8 kW cooling
9 kW heating

5% less electricity than the median of 120 comparable 8 kW reverse cycle split system registrations (3,622 kWh a year) in the cold zone. Uses less than 77% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 55% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Panasonic CU-Z80DKR running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,422$1,129$11,293
Mixed zone 1,753$578$5,785
Hot zone 2,081$687$6,867

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 8 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-71PZ3R5 / S-6071PU3E7.1 kW heating7.1 kW cooling2,650 kWh/yr3$875
Panasonic U-71PZ4R5 / S-6071PU3E7.1 kW heating7.1 kW cooling2,665 kWh/yr3$879
Daikin RZAV71CV1 / FCTA71AVMA8 kW heating7.1 kW cooling2,676 kWh/yr0.5$883
Mdv C-UV-74N8-QC3W / CSV-72N8-QC7W7.7 kW heating7.2 kW cooling2,745 kWh/yr4$906
Daikin RXM71AVMA / FTXM71AVMA8 kW heating7.1 kW cooling2,764 kWh/yr3.5$912

Heat pumps similar to the Panasonic CU-Z80DKR

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Kogan KASSSAC80HD8.2 kW heating8 kW cooling3,283 kWh/yr4.5$1,083
Hisense HAWG28KR8 kW heating8 kW cooling3,466 kWh/yr3$1,144
Kogan KASSSAC80HF8.2 kW heating8 kW cooling3,283 kWh/yr4.5$1,083
Solar Acdc DGWA1-ACDCBLW-30KR29 kW heating8 kW cooling3,418 kWh/yr4$1,128
Carrier 38QHG080N8-1/42QHG080N8-18.2 kW heating8 kW cooling3,371 kWh/yr3.5$1,112
Carrier 38QAG080N8/42QAG080N88.2 kW heating8 kW cooling3,371 kWh/yr3.5$1,112
Haier 1U80QAFFRA / AS80QFFHRA9 kW heating8 kW cooling3,455 kWh/yr3.5$1,140
Hisense HAWJ28KR8 kW heating8 kW cooling3,466 kWh/yr3$1,144

Compare CU-Z80DKR / CS-Z80DKR with another model

Panasonic CU-Z80DKR specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
8.00 kW
Cooling power input
2.39 kW
Rated heating capacity (7 Β°C)
9.00 kW
Heating power input
2.34 kW
EER, full load (tested)
3.47
COP, full load (tested)
3.80
Rated AEER
3.34
Rated ACOP
3.83
Standby power (PIA)
2.5 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
67 dB(A)
Outdoor sound power
69 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic CU-Z80DKR zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––772938
Coldresidential3.52.04033,019
Mixedcommercial––1,036481
Mixedresidential3.52.56521,101
Hotcommercial––2,48197
Hotresidential3.53.51,929152
Part-load test points (23 values)
c__t1_min_cap_power_rated
460 W
h__h1_min_cap_power_rated
430 W
h__h2_ext_cap_power_rated
2750 W
c__t1_half_cap_power_rated
760 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
820 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2200 W
h__h2_ext_cap_heat_cap_rated
8200 W
h__h1_half_cap_heat_cap_rated
4500 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
390 W
c__t1_min_cap_cooling_cap_rated
2300 W
c__low_temp_half_cap_power_rated
640 W
c__t1_half_cap_cooling_cap_rated
4000 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2680 W
c__low_temp_half_cap_cooling_cap_rated
4300 W

Other model numbers on registration AAC10227

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC10227
GEMS registration id
179416
Status
approved, available (self-reported)
Registration expires
4 June 2031
Registered for sale in
Australia, New Zealand
Family
CU-*Z80DKR / CU-*Z80DKR
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: papamy.panasonic.com.my. How the derived figures are calculated.