c/kWh
Energy rating (cooling)
3.5
Heating: 2.5
Annual electricity use
3,848 kWh
471 cooling + 3,377 heating
Estimated running cost
$1,270 / year
$106 / month Β· $12,698 over 10 years
Capacity
9.5 kW cooling
10.8 kW heating

19% less electricity than the median of 135 comparable 10 kW reverse cycle ducted split system registrations (4,767 kWh a year) in the cold zone. Uses less than 91% of them.

Across all 3,566 air conditioner registrations sold in Australia, it uses less than 49% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Panasonic U-100PZH3R8 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,848$1,270$12,698
Mixed zone 2,017$666$6,656
Hot zone 2,262$746$7,465

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 9.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Fujitsu AOTH30KCTA/ARTH30KMTAP10 kW heating8.5 kW cooling0 kWh/yr–$0
Fujitsu AOTH30KBTA/ARTH30KMTAP10 kW heating8.5 kW cooling0 kWh/yr–$0
Panasonic U-100PZ4R8 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr3$1,199
Panasonic U-100PZ3R5 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr3$1,199
Carrier 38QSM090D8S/42QSM090D8S9.3 kW heating8.7 kW cooling3,653 kWh/yr3.5$1,205

Heat pumps similar to the Panasonic U-100PZH3R8

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
LG UU100WR2 U30/UMN100M2 N2010.8 kW heating9.5 kW cooling5,594 kWh/yr2$1,846
LG UU100WR3 U30/UMN100M2 N2010.8 kW heating9.5 kW cooling4,493 kWh/yr2.5$1,483
Carrier 38QSP090N8/42QSP090N810.5 kW heating9 kW cooling3,834 kWh/yr3.5$1,265
Midea UCMI105OB/DUCMI105IHB11 kW heating10 kW cooling4,227 kWh/yr4.5$1,395
Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling3,687 kWh/yr3.5$1,217
Rinnai DONSR09B1/DINLR09B110 kW heating9 kW cooling3,660 kWh/yr4$1,208

Other Panasonic models of similar capacity

ModelStarsEst. cost / yrCompare
Panasonic U-100PZ4R8 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr3$1,199
Panasonic U-100PZ3R8 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr3$1,199

Compare U-100PZH3R8/S-1014PF3E with another model

Panasonic U-100PZH3R8 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
9.50 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
10.80 kW
Heating power input
–
EER, full load (tested)
4.35
COP, full load (tested)
4.18
Rated AEER
4.08
Rated ACOP
3.90
Standby power (PIA)
15.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-100PZH3R8 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––9231,054
Coldresidential3.52.54713,377
Mixedcommercial––1,181558
Mixedresidential3.53.07301,287
Hotcommercial––2,674131
Hotresidential4.04.02,062200
Part-load test points (22 values)
h__h1_min_cap_power_rated
545 W
h__h2_ext_cap_power_rated
4140 W
c__t1_half_cap_power_rated
870 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
970 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3200 W
h__h2_ext_cap_heat_cap_rated
12000 W
h__h1_half_cap_heat_cap_rated
5400 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
440 W
c__low_temp_half_cap_power_rated
715 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
4750 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3550 W
c__low_temp_half_cap_cooling_cap_rated
5100 W

New Zealand E3 registration details

Registration number
AAC9624
GEMS registration id
–
Status
approved
Registration expires
8 December 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
10

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.