c/kWh
Energy rating (cooling)
3
Heating: 2
Annual electricity use
5,098 kWh
722 cooling + 4,376 heating
Estimated running cost
$1,682 / year
$140 / month Β· $16,823 over 10 years
Capacity
12.5 kW cooling
12.5 kW heating

14% less electricity than the median of 81 comparable 12.5 kW reverse cycle split system registrations (5,949 kWh a year) in the cold zone. Uses less than 82% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 38% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Panasonic U-125PZ3R8 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,098$1,682$16,823
Mixed zone 2,712$895$8,950
Hot zone 3,483$1,149$11,494

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 12.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-125PZ4R8 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Panasonic U-125PZ4R5 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528

Heat pumps similar to the Panasonic U-125PZ3R8

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hitachi PAS-5.0UFASNQ1 / PCI-5.0UFA1NQ14 kW heating12.5 kW cooling5,602 kWh/yr3.5$1,849
Daikin RZAV125FY1 / FCA125CVMA15 kW heating12.5 kW cooling5,137 kWh/yr4$1,695
Mitsubishi Heavy Industries FDC125VSX-W / FDE125VH14 kW heating12.5 kW cooling5,469 kWh/yr2.5$1,805
Daikin RZAV125FV1 / FCTA125AVMA15 kW heating12.5 kW cooling5,020 kWh/yr4$1,657
Mitsubishi Heavy Industries FDCA125VSX-W / FDE125VH14 kW heating12.5 kW cooling5,469 kWh/yr2.5$1,805
Mdv C-UV-125N8-QC3W / CSV-125N8-QC3W13 kW heating12.5 kW cooling5,013 kWh/yr4$1,654
Hitachi PAS-5.0UFASMQ1 / PCI-5.0UFA1NQ14 kW heating12.5 kW cooling5,594 kWh/yr3$1,846
Kaden KDI42 / KCI4213 kW heating12.5 kW cooling5,013 kWh/yr4$1,654

Compare U-125PZ3R8/S-1014PT3E with another model

Panasonic U-125PZ3R8 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Floor / ceiling
Rated cooling capacity (35 Β°C)
12.50 kW
Cooling power input
3.76 kW
Rated heating capacity (7 Β°C)
12.50 kW
Heating power input
3.21 kW
EER, full load (tested)
3.30
COP, full load (tested)
3.84
Rated AEER
3.27
Rated ACOP
3.81
Standby power (PIA)
20.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Dimensions (WΓ—HΓ—D)
1590 Γ— 235 Γ— 690 mm
Country of manufacture
Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-125PZ3R8 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,4201,336
Coldresidential3.02.07224,376
Mixedcommercial––1,826678
Mixedresidential2.52.51,1351,577
Hotcommercial––4,210161
Hotresidential3.03.53,238245
Part-load test points (22 values)
h__h1_min_cap_power_rated
550 W
h__h2_ext_cap_power_rated
4350 W
c__t1_half_cap_power_rated
1290 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1180 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3100 W
h__h2_ext_cap_heat_cap_rated
11200 W
h__h1_half_cap_heat_cap_rated
6250 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
535 W
c__low_temp_half_cap_power_rated
1120 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
6250 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3700 W
c__low_temp_half_cap_cooling_cap_rated
6900 W

New Zealand E3 registration details

Registration number
AAC9776
GEMS registration id
175918
Status
approved, available (self-reported)
Registration expires
7 February 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.