c/kWh
Energy rating (cooling)
2
Heating: 2
Annual electricity use
1,506 kWh
237 cooling + 1,269 heating
Estimated running cost
$497 / year
$41 / month Β· $4,970 over 10 years
Capacity
3.6 kW cooling
3.6 kW heating

8% more electricity than the median of 180 comparable 3.5 kW reverse cycle split system registrations (1,395 kWh a year) in the cold zone. Uses less than 34% of them.

Across all 3,566 air conditioner registrations sold in Australia, it uses less than 81% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Panasonic U-36PZ3R5 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,506$497$4,970
Mixed zone 841$278$2,775
Hot zone 1,058$349$3,491

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 3.6 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Midea MFCA35VA-W/MFCA35VA-N3.6 kW heating3.5 kW cooling1,144 kWh/yr5.5$378
Daikin RXM35AVMA / FTXM35AVMA3.7 kW heating3.5 kW cooling1,146 kWh/yr5.5$378
Midea MFEP35VA-W/MFEP35VA-N3.6 kW heating3.5 kW cooling1,183 kWh/yr6$390
Daikin RXV35AVMA / FTXV35AVMA3.7 kW heating3.5 kW cooling1,207 kWh/yr5$398
Hitachi RAC-VJ35PHAT/RAK-VJ35PHAT3.8 kW heating3.5 kW cooling1,209 kWh/yr5$399

Heat pumps similar to the Panasonic U-36PZ3R5

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Toshiba RAV-GM401ATP-A/RAV-HM401MUTP-E4 kW heating3.6 kW cooling1,689 kWh/yr2.5$557
Midea MFAB-60WC/MULMIO123.9 kW heating3.6 kW cooling1,383 kWh/yr4$456
Toshiba RAV-GM401ATP-A/RAV-GM401KRTP-A4 kW heating3.6 kW cooling1,883 kWh/yr3$621
Westinghouse WSD36HWA-E/WSD36HWA-I4.4 kW heating3.6 kW cooling1,411 kWh/yr5.5$466
Spt AW036C-1/AW036E3.9 kW heating3.6 kW cooling1,246 kWh/yr5.5$411
Westinghouse WSD36HWB-I/WSD36HWA-E4.4 kW heating3.6 kW cooling1,411 kWh/yr5.5$466
Midea MFCA35VA-W/MFCA35VA-N3.6 kW heating3.5 kW cooling1,144 kWh/yr5.5$378
Aux ASW-H36A4/CAR3DI3.8 kW heating3.5 kW cooling1,303 kWh/yr5.5$430

Compare U-36PZ3R5/S-36PY3E with another model

Panasonic U-36PZ3R5 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Cassette
Rated cooling capacity (35 Β°C)
3.60 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
3.60 kW
Heating power input
–
EER, full load (tested)
3.99
COP, full load (tested)
4.30
Rated AEER
3.80
Rated ACOP
4.10
Standby power (PIA)
11.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
–

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-36PZ3R5 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––485409
Coldresidential2.02.02371,269
Mixedcommercial––604220
Mixedresidential2.02.5357484
Hotcommercial––1,27861
Hotresidential3.03.096989
Part-load test points (20 values)
h__h1_min_cap_power_rated
250 W
c__t1_half_cap_power_rated
420 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
350 W
h__h1_have_min_cap_results
Yes
h__h2_full_cap_power_rated
1170 W
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1300 W
h__h1_half_cap_heat_cap_rated
1800 W
h__h2_full_cap_heat_cap_rated
3340 W
h__h2_is_capable_extended_load
No
c__low_temp_min_cap_power_rated
280 W
c__low_temp_half_cap_power_rated
360 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
1800 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
1500 W
c__low_temp_half_cap_cooling_cap_rated
2000 W

New Zealand E3 registration details

Registration number
AAC10461
GEMS registration id
–
Status
approved
Registration expires
17 October 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
8

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.