c/kWh
Energy rating (cooling)
2
Heating: 2
Annual electricity use
1,506 kWh
237 cooling + 1,269 heating
Estimated running cost
$497 / year
$41 / month Β· $4,970 over 10 years
Capacity
3.6 kW cooling
3.6 kW heating

8% more electricity than the median of 187 comparable 3.5 kW reverse cycle split system registrations (1,395 kWh a year) in the cold zone. Uses less than 34% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 81% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Panasonic U-36PZ3R5 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,506$497$4,970
Mixed zone 841$278$2,775
Hot zone 1,058$349$3,491

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 3.6 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Midea MFCA35VA-W/MFCA35VA-N3.6 kW heating3.5 kW cooling1,144 kWh/yr5.5$378
Daikin RXM35AVMA / FTXM35AVMA3.7 kW heating3.5 kW cooling1,146 kWh/yr5.5$378
Midea MFEP35VA-W/MFEP35VA-N3.6 kW heating3.5 kW cooling1,183 kWh/yr6$390
Daikin RXV35AVMA / FTXV35AVMA3.7 kW heating3.5 kW cooling1,207 kWh/yr5$398
Hitachi RAC-VJ35PHAT/RAK-VJ35PHAT3.8 kW heating3.5 kW cooling1,209 kWh/yr5$399

Heat pumps similar to the Panasonic U-36PZ3R5

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Toshiba RAV-GM401ATP-A/RAV-HM401MUTP-E4 kW heating3.6 kW cooling1,689 kWh/yr2.5$557
Midea MFAB-60WC/MULMIO123.9 kW heating3.6 kW cooling1,383 kWh/yr4$456
Toshiba RAV-GM401ATP-A/RAV-GM401KRTP-A4 kW heating3.6 kW cooling1,883 kWh/yr3$621
Westinghouse HSV127HWAE/HSV127HWAI4.4 kW heating3.6 kW cooling1,411 kWh/yr5.5$466
Westinghouse WSD36HWB-I/WSD36HWA-E4.4 kW heating3.6 kW cooling1,411 kWh/yr5.5$466
Spt AW036C-1/AW036E3.9 kW heating3.6 kW cooling1,246 kWh/yr5.5$411
Midea MFCA35VA-W/MFCA35VA-N3.6 kW heating3.5 kW cooling1,144 kWh/yr5.5$378
Aux ASW-H36A4/CAR3DI3.8 kW heating3.5 kW cooling1,303 kWh/yr5.5$430

Compare U-36PZ3R5/S-36PY3E with another model

Panasonic U-36PZ3R5 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Cassette
Rated cooling capacity (35 Β°C)
3.60 kW
Cooling power input
0.91 kW
Rated heating capacity (7 Β°C)
3.60 kW
Heating power input
0.84 kW
EER, full load (tested)
3.99
COP, full load (tested)
4.30
Rated AEER
3.80
Rated ACOP
4.10
Standby power (PIA)
11.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Dimensions (WΓ—HΓ—D)
840 Γ— 256 Γ— 840 mm
Country of manufacture
Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-36PZ3R5 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––485409
Coldresidential2.02.02371,269
Mixedcommercial––604220
Mixedresidential2.02.5357484
Hotcommercial––1,27861
Hotresidential3.03.096989
Part-load test points (20 values)
h__h1_min_cap_power_rated
250 W
c__t1_half_cap_power_rated
420 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
350 W
h__h1_have_min_cap_results
Yes
h__h2_full_cap_power_rated
1170 W
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1300 W
h__h1_half_cap_heat_cap_rated
1800 W
h__h2_full_cap_heat_cap_rated
3340 W
h__h2_is_capable_extended_load
No
c__low_temp_min_cap_power_rated
280 W
c__low_temp_half_cap_power_rated
360 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
1800 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
1500 W
c__low_temp_half_cap_cooling_cap_rated
2000 W

New Zealand E3 registration details

Registration number
AAC10461
GEMS registration id
182218
Status
approved, available (self-reported)
Registration expires
17 October 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 22 September 2026; last checked 23 September 2026. How the derived figures are calculated.