c/kWh
Energy rating (cooling)
2.5
Heating: 2
Annual electricity use
2,764 kWh
422 cooling + 2,342 heating
Estimated running cost
$912 / year
$76 / month Β· $9,121 over 10 years
Capacity
6.8 kW cooling
6.8 kW heating

16% less electricity than the median of 80 comparable 7 kW reverse cycle ducted split system registrations (3,279 kWh a year) in the cold zone. Uses less than 93% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 65% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Panasonic U-71PZ3R5 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,764$912$9,121
Mixed zone 1,515$500$5,000
Hot zone 2,060$680$6,798

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 6.8 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-60PZ4R5 / S-60PE4R6 kW heating6 kW cooling2,446 kWh/yr2.5$807
Panasonic U-60PZ3R5/S-60PE3R6 kW heating6 kW cooling2,651 kWh/yr2$875
Daikin RZAC60GBV1 / FDYBA60AV17 kW heating6 kW cooling2,674 kWh/yr2.5$882
Daikin RZAC60GV1 / FDYBA60AV17 kW heating6 kW cooling2,674 kWh/yr2.5$882

Heat pumps similar to the Panasonic U-71PZ3R5

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
LG UU70WR2 U40/UMN70M1 N107.5 kW heating6.8 kW cooling4,379 kWh/yr1.5$1,445
Carrier 38QSM070D8S/42QSM070D8S7.1 kW heating7.1 kW cooling2,829 kWh/yr3.5$934
Hyundai HYDCTAC71TB7.5 kW heating7.1 kW cooling2,770 kWh/yr3.5$914
TCL TCD71D1HWH-DVO/TCD71D1HWH-DVI7.5 kW heating7.1 kW cooling2,770 kWh/yr3.5$914
Hyundai HYDCTAC71TC7.5 kW heating7.1 kW cooling2,770 kWh/yr3.5$914
Daikin RZAS71C2V1 / FDYA71AV197.5 kW heating7.1 kW cooling2,974 kWh/yr3$981

Other Panasonic models of similar capacity

ModelStarsEst. cost / yrCompare
Panasonic U-71PZH3R5/S-6071PF3E7.5 kW heating6.8 kW cooling2,766 kWh/yr3$913
Panasonic U-71PZ4R5 / S-6071PF3E6.8 kW heating6.8 kW cooling2,674 kWh/yr3$882

Compare U-71PZ3R5 / S-6071PF3E with another model

Panasonic U-71PZ3R5 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
6.80 kW
Cooling power input
2.14 kW
Rated heating capacity (7 Β°C)
6.80 kW
Heating power input
1.70 kW
EER, full load (tested)
3.19
COP, full load (tested)
3.81
Rated AEER
3.14
Rated ACOP
3.94
Standby power (PIA)
8.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China, Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-71PZ3R5 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––798718
Coldresidential2.52.04222,342
Mixedcommercial––1,043367
Mixedresidential2.52.5658857
Hotcommercial––2,53283
Hotresidential3.03.51,932128
Part-load test points (21 values)
c__t1_min_cap_power_rated
570 W
h__h1_min_cap_power_rated
370 W
h__h2_ext_cap_power_rated
2150 W
c__t1_half_cap_power_rated
760 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
680 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2100 W
h__h2_ext_cap_heat_cap_rated
6100 W
h__h1_half_cap_heat_cap_rated
3400 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
470 W
c__t1_min_cap_cooling_cap_rated
2600 W
c__t1_half_cap_cooling_cap_rated
3400 W
c__low_temp_have_half_cap_results
No
c__low_temp_min_cap_cooling_cap_rated
2900 W

New Zealand E3 registration details

Registration number
AAC9046
GEMS registration id
169369
Status
approved, available (self-reported)
Registration expires
27 September 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 10

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: papamy.panasonic.com.my. How the derived figures are calculated.