c/kWh
Energy rating (cooling)
2.5
Heating: 2
Annual electricity use
3,229 kWh
448 cooling + 2,781 heating
Estimated running cost
$1,066 / year
$89 / month Β· $10,656 over 10 years
Capacity
7.1 kW cooling
8 kW heating

1% less electricity than the median of 80 comparable 7 kW reverse cycle ducted split system registrations (3,264 kWh a year) in the cold zone. Uses less than 58% of them.

Across all 3,566 air conditioner registrations sold in Australia, it uses less than 59% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Panasonic U-71PZH3R5 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,229$1,066$10,656
Mixed zone 1,757$580$5,798
Hot zone 2,126$702$7,016

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 7.1 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Fujitsu AOTH24KCTA/ARTH24KMTAP8 kW heating7.1 kW cooling0 kWh/yr–$0
Fujitsu AOTH24KBTA/ARTH24KMTAP8 kW heating7.1 kW cooling0 kWh/yr–$0
Panasonic U-71PZ4R5 / S-6071PF3E6.8 kW heating6.8 kW cooling2,674 kWh/yr3$882
Rinnai DONSR07B1/DINLR07B17.5 kW heating7.3 kW cooling2,720 kWh/yr3.5$898
Mdv C-UV-74N8-QC3W / CDV-74A6N8-QC3W7.5 kW heating7.4 kW cooling2,744 kWh/yr3.5$906

Heat pumps similar to the Panasonic U-71PZH3R5

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hyundai HYDCTAC71TB7.5 kW heating7.1 kW cooling2,770 kWh/yr3.5$914
Hyundai HYDCTAC71TD7.5 kW heating7.1 kW cooling2,770 kWh/yr3.5$914
Gree GFH24ACXF-S6DNE3D/O / GFH24ACXF-S6DNE3D/I7.6 kW heating7.1 kW cooling3,127 kWh/yr3$1,032
Fujitsu AOTH24KCTA/ARTH24KMTAP8 kW heating7.1 kW cooling0 kWh/yr–$0
Fujitsu AOTH24KBTA/ARTH24KMTAP8 kW heating7.1 kW cooling0 kWh/yr–$0
Daikin RZAS71C2V1 / FDYA71AV197.5 kW heating7.1 kW cooling2,974 kWh/yr3$981
Daikin RZAS71C2V1 / FDYUA71AV197.5 kW heating7.1 kW cooling2,974 kWh/yr3$981
TCL TCD71D1HWH-DVO/TCD71D1HWH-DVI7.5 kW heating7.1 kW cooling2,770 kWh/yr3.5$914

Compare U-71PZH3R5/S-71PE3R with another model

Panasonic U-71PZH3R5 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
7.10 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
8.00 kW
Heating power input
–
EER, full load (tested)
3.55
COP, full load (tested)
4.19
Rated AEER
3.41
Rated ACOP
3.81
Standby power (PIA)
12.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-71PZH3R5 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––942881
Coldresidential2.52.04482,781
Mixedcommercial––1,197468
Mixedresidential2.52.56971,060
Hotcommercial––2,561111
Hotresidential3.03.01,957169
Part-load test points (22 values)
h__h1_min_cap_power_rated
420 W
h__h2_ext_cap_power_rated
2860 W
c__t1_half_cap_power_rated
850 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
830 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2100 W
h__h2_ext_cap_heat_cap_rated
8000 W
h__h1_half_cap_heat_cap_rated
4000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
430 W
c__low_temp_half_cap_power_rated
700 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
3600 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2100 W
c__low_temp_half_cap_cooling_cap_rated
3950 W

New Zealand E3 registration details

Registration number
AAC9605
GEMS registration id
–
Status
approved
Registration expires
1 December 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
10

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.