c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
7,403 kWh
918 cooling + 6,485 heating
Estimated running cost
$2,443 / year
$204 / month Β· $24,430 over 10 years
Capacity
17 kW cooling
18 kW heating

12% less electricity than the median of 51 comparable 18 kW reverse cycle ducted split system registrations (8,396 kWh a year) in the cold zone. Uses less than 69% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 22% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Rinnai DONSR18B1 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 7,403$2,443$24,430
Mixed zone 3,764$1,242$12,421
Hot zone 4,431$1,462$14,622

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 17 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RZA160CV1 / FDYAN160AV118 kW heating15.5 kW cooling4,493 kWh/yr2$1,483
Carrier 38QSH170D8S / 42QSH170D8S17 kW heating17 kW cooling6,907 kWh/yr3.5$2,279
Midea DUCMI170IHB/UCMI170OB17.5 kW heating17 kW cooling7,066 kWh/yr4$2,332
Midea DUCMI170IHB/UCMI170OB17.5 kW heating17 kW cooling7,066 kWh/yr4$2,332
Actron Air LRC-170CS / LRE-170CS17.6 kW heating16.6 kW cooling7,156 kWh/yr4$2,361

Heat pumps similar to the Rinnai DONSR18B1

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Actron Air CRV17BT / EVV17BS17.2 kW heating17 kW cooling7,384 kWh/yr3$2,437
Midea DUCMI170IHB/UCMI170OB17.5 kW heating17 kW cooling7,066 kWh/yr4$2,332
Carrier 38QSV170N8/42QSV170N8S18 kW heating17 kW cooling7,212 kWh/yr3.5$2,380
Kaden KDI60 / KDI6018 kW heating17 kW cooling7,317 kWh/yr4$2,415
Actron Air LRC-170DS / LRE-170DS18 kW heating17 kW cooling7,212 kWh/yr3.5$2,380
Carrier 38QSH170D8S / 42QSH170D8S17 kW heating17 kW cooling6,907 kWh/yr3.5$2,279
Kaden KDI-17.018 kW heating17 kW cooling7,212 kWh/yr3.5$2,380
Midea DUCMI170IHB/UCMI170OB17.5 kW heating17 kW cooling7,066 kWh/yr4$2,332

Compare DONSR18B1/DINLR18B1 with another model

Rinnai DONSR18B1 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
17.00 kW
Cooling power input
5.25 kW
Rated heating capacity (7 Β°C)
18.00 kW
Heating power input
4.55 kW
EER, full load (tested)
3.30
COP, full load (tested)
3.92
Rated AEER
3.21
Rated ACOP
3.92
Standby power (PIA)
13.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
70.9 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Rinnai DONSR18B1 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––3461,969
Coldresidential3.52.09186,485
Mixedcommercial––1,180987
Mixedresidential3.02.51,4472,317
Hotcommercial––2,849210
Hotresidential3.53.54,101330
Part-load test points (25 values)
c__t1_min_cap_power_rated
1100 W
h__h1_min_cap_power_rated
780 W
h__h2_ext_cap_power_rated
4950 W
c__t1_half_cap_power_rated
2720 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1720 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
4130 W
h__h2_ext_cap_heat_cap_rated
14510 W
h__h1_half_cap_heat_cap_rated
8670 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
630 W
c__t1_min_cap_cooling_cap_rated
4490 W
c__low_temp_full_cap_power_rated
4798.5 W
c__low_temp_half_cap_power_rated
1556 W
c__t1_half_cap_cooling_cap_rated
8030 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
4050 W
c__low_temp_full_cap_cooling_cap_rated
18309 W
c__low_temp_half_cap_cooling_cap_rated
8250 W

2 model numbers on 2 other registrations. Variants registered separately can carry different star ratings and energy figures; check the registration number on the label.

ModelRegistrationStarskWh / yr
DONSR18B1/DINLR18B1AAC672047,317
DONSR18B1/DINLR18B1AAC814547,316

New Zealand E3 registration details

Registration number
AAC8199
GEMS registration id
161055
Status
approved, available (self-reported)
Registration expires
1 May 2029
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11