c/kWh
Energy rating (cooling)
4
Heating: 2
Annual electricity use
5,827 kWh
612 cooling + 5,215 heating
Estimated running cost
$1,923 / year
$160 / month Β· $19,229 over 10 years
Capacity
12.5 kW cooling
14 kW heating

5% less electricity than the median of 146 comparable 12.5 kW reverse cycle ducted split system registrations (6,125 kWh a year) in the cold zone. Uses less than 69% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 32% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

TECO TDS-TSO125HVSWDG running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,827$1,923$19,229
Mixed zone 2,751$908$9,078
Hot zone 3,168$1,045$10,454

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 12.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Brivis AONSR13B1/AINHU13B113.8 kW heating12 kW cooling4,365 kWh/yr4.5$1,440
Panasonic U-125PZ3R8 / S-1014PF3E12.1 kW heating12.1 kW cooling4,458 kWh/yr3$1,471
Panasonic U-125PZ4R8 / S-125PE4*12.5 kW heating12.5 kW cooling4,742 kWh/yr3$1,565
Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling4,776 kWh/yr4$1,576
Carrier 38QSM125D8S/42QSM125D8S13 kW heating12.3 kW cooling4,798 kWh/yr3.5$1,583

Heat pumps similar to the TECO TDS-TSO125HVSWDG

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Kaden KDI4213 kW heating12.5 kW cooling4,853 kWh/yr3.5$1,601
Mdv C-UV-125N8-QC3W / CDV-125A6N8-QC3W13.5 kW heating12.5 kW cooling4,988 kWh/yr3.5$1,646
Panasonic U-125PZ4R5 / S-125PE4RN12.5 kW heating12.5 kW cooling4,742 kWh/yr3$1,565
Kaden KDI42 / KDI4213 kW heating12.5 kW cooling4,853 kWh/yr3.5$1,601
Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling4,776 kWh/yr4$1,576
Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling4,848 kWh/yr3.5$1,600
Rinnai DONSR13B1/DINLR13B113 kW heating12.5 kW cooling4,830 kWh/yr4$1,594
Panasonic U-125PZ4R8 / S-125PE4R12.5 kW heating12.5 kW cooling4,742 kWh/yr3$1,565

Compare TDS-TSO125HVSWDG with another model

TECO TDS-TSO125HVSWDG specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
12.50 kW
Cooling power input
3.68 kW
Rated heating capacity (7 Β°C)
14.00 kW
Heating power input
3.68 kW
EER, full load (tested)
3.37
COP, full load (tested)
3.74
Rated AEER
3.38
Rated ACOP
3.79
Standby power (PIA)
5.1 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

TECO TDS-TSO125HVSWDG zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––5021,609
Coldresidential4.02.06125,215
Mixedcommercial––731761
Mixedresidential3.52.59591,792
Hotcommercial––3,132151
Hotresidential4.03.52,932236
Part-load test points (25 values)
c__t1_min_cap_power_rated
720 W
h__h1_min_cap_power_rated
620 W
h__h2_ext_cap_power_rated
3600 W
c__t1_half_cap_power_rated
1250 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1250 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3200 W
h__h2_ext_cap_heat_cap_rated
10300 W
h__h1_half_cap_heat_cap_rated
7000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
390 W
c__t1_min_cap_cooling_cap_rated
2500 W
c__low_temp_full_cap_power_rated
3363.52 W
c__low_temp_half_cap_power_rated
1142.5 W
c__t1_half_cap_cooling_cap_rated
6250 W
c__low_temp_have_half_cap_results
No
c__low_temp_min_cap_cooling_cap_rated
2400 W
c__low_temp_full_cap_cooling_cap_rated
13462.5 W
c__low_temp_half_cap_cooling_cap_rated
6731.25 W

New Zealand E3 registration details

Registration number
AAC8387
GEMS registration id
156343
Status
approved, available (self-reported)
Registration expires
11 August 2029
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: teco.com.au. How the derived figures are calculated.