New Zealand Β· costs in NZD
Reverse cycle split system air conditioner
Z Zentri ZDA-125INV-AU Heat Pump
Z Zentri ZDA-125INV-AU is a 12.5 kW reverse cycle ducted split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC9978).
- Energy rating (cooling)
- 3
- Heating: 2
- Annual electricity use
- 6,332 kWh
- 751 cooling + 5,581 heating
- Estimated running cost
- $2,090 / year
- $174 / month Β· $20,896 over 10 years
- Capacity
- 12.5 kW cooling
- 15 kW heating
3% more electricity than the median of 146 comparable 12.5 kW reverse cycle ducted split system registrations (6,125 kWh a year) in the cold zone. Uses less than 42% of them.
Across all 3,612 air conditioner registrations sold in Australia, it uses less than 29% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Z Zentri ZDA-125INV-AU running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 6,332 | $2,090 | $20,896 |
| Mixed zone | 3,189 | $1,052 | $10,524 |
| Hot zone | 3,748 | $1,237 | $12,368 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 12.5 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Brivis AONSR13B1/AINHU13B113.8 kW heating12 kW cooling4,365 kWh/yr | 4.5 | $1,440 | |
| Panasonic U-125PZ3R8 / S-1014PF3E12.1 kW heating12.1 kW cooling4,458 kWh/yr | 3 | $1,471 | |
| Panasonic U-125PZ4R8 / S-125PE4*12.5 kW heating12.5 kW cooling4,742 kWh/yr | 3 | $1,565 | |
| Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling4,776 kWh/yr | 4 | $1,576 | |
| Carrier 38QSM125D8S/42QSM125D8S13 kW heating12.3 kW cooling4,798 kWh/yr | 3.5 | $1,583 |
Heat pumps similar to the Z Zentri ZDA-125INV-AU
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Kaden KDI4213 kW heating12.5 kW cooling4,853 kWh/yr | 3.5 | $1,601 | |
| Mdv C-UV-125N8-QC3W / CDV-125A6N8-QC3W13.5 kW heating12.5 kW cooling4,988 kWh/yr | 3.5 | $1,646 | |
| Panasonic U-125PZ4R5 / S-125PE4RN12.5 kW heating12.5 kW cooling4,742 kWh/yr | 3 | $1,565 | |
| Kaden KDI42 / KDI4213 kW heating12.5 kW cooling4,853 kWh/yr | 3.5 | $1,601 | |
| Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling4,776 kWh/yr | 4 | $1,576 | |
| Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling4,848 kWh/yr | 3.5 | $1,600 | |
| Rinnai DONSR13B1/DINLR13B113 kW heating12.5 kW cooling4,830 kWh/yr | 4 | $1,594 | |
| Panasonic U-125PZ4R8 / S-125PE4R12.5 kW heating12.5 kW cooling4,742 kWh/yr | 3 | $1,565 |
Compare ZDA-125INV-AU with another model
Z Zentri ZDA-125INV-AU specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 12.50 kW
- Cooling power input
- 3.80 kW
- Rated heating capacity (7 Β°C)
- 15.00 kW
- Heating power input
- 3.75 kW
- EER, full load (tested)
- 3.30
- COP, full load (tested)
- 3.99
- Rated AEER
- 3.27
- Rated ACOP
- 3.97
- Standby power (PIA)
- 8.3 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- 70.3 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Z Zentri ZDA-125INV-AU zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,466 | 1,748 |
| Coldresidential | residential | 3.0 | 2.0 | 751 | 5,581 |
| Mixedcommercial | commercial | β | β | 1,944 | 889 |
| Mixedresidential | residential | 2.5 | 2.5 | 1,184 | 2,005 |
| Hotcommercial | commercial | β | β | 4,465 | 187 |
| Hotresidential | residential | 3.0 | 3.0 | 3,455 | 293 |
Part-load test points (18 values)
- h__h2_ext_cap_power_rated
- 4480 W
- c__t1_half_cap_power_rated
- 1450 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 1400 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 12250 W
- h__h1_half_cap_heat_cap_rated
- 7000 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_half_cap_power_rated
- 1180 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 6200 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_half_cap_cooling_cap_rated
- 6550 W
New Zealand E3 registration details
- Registration number
- AAC9978
- GEMS registration id
- 178225
- Status
- approved, available (self-reported)
- Registration expires
- 24 March 2031
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 11