c/kWh
Energy rating (cooling)
4
Heating: 2.5
Annual electricity use
2,151 kWh
724 cooling + 1,427 heating
Estimated running cost
$688 / year
$57 / month Β· $6,883 over 10 years
Capacity
10.5 kW cooling
11.5 kW heating

11% less electricity than the median of 129 comparable 10 kW reverse cycle ducted split system registrations (2,429 kWh a year) in the mixed zone. Uses less than 86% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 48% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Aurora running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,349$1,392$13,917
Mixed zone 2,151$688$6,883
Hot zone 2,070$662$6,624

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 10.5 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Panasonic U-100PZ4R8 / S-100PE4RN10 kW heating10 kW cooling1,449 kWh/yr2.5$464
Panasonic U-100PZ4R8 / S-100PE4R10 kW heating10 kW cooling1,449 kWh/yr2.5$464
Brivis AONSR13B1/AINHU11B111.3 kW heating10.3 kW cooling1,881 kWh/yr4.5$602

Air conditioners similar to the Aurora

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Kaden KDI3611.5 kW heating10.5 kW cooling2,325 kWh/yr3$744
Midea UCMI90OB/DUCMI90IB11 kW heating10.5 kW cooling2,122 kWh/yr4$679
Kaden KDI36 / KDI3611.5 kW heating10.5 kW cooling2,174 kWh/yr4$696
Actron Air LRC-100CS / LRE-100CS11.5 kW heating10.5 kW cooling2,126 kWh/yr4$680
Mdv C-UV-105N8-QC3W / CDV-105HN8-QC3W11 kW heating10.5 kW cooling2,126 kWh/yr4$680
Rinnai DONSR11B1/DINLR11B111.5 kW heating10.5 kW cooling2,165 kWh/yr4$693
Mdv C-UV-105N8-QC3W / CDV-105A6N8-QC3W11 kW heating10.5 kW cooling2,135 kWh/yr4$683
Rinnai DONSR11B1/DINLR11B111.5 kW heating10.5 kW cooling2,164 kWh/yr4$692

Compare AU-BS36HR-2A-O / AU-LCF36-2A-I with another model

Aurora specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
10.50 kW
Cooling power input
3.20 kW
Rated heating capacity (7 Β°C)
11.50 kW
Heating power input
2.70 kW
EER, full load (tested)
3.31
COP, full load (tested)
4.18
Rated AEER
3.25
Rated ACOP
4.21
Standby power (PIA)
10.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
72 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Aurora zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––-1291,211
Coldresidential4.52.04483,901
Mixedcommercial––1,167619
Mixedresidential4.02.57241,427
Hotcommercial––1,045137
Hotresidential5.53.51,856214
Part-load test points (25 values)
c__t1_min_cap_power_rated
750 W
h__h1_min_cap_power_rated
490 W
h__h2_ext_cap_power_rated
3500 W
c__t1_half_cap_power_rated
1850 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1150 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2600 W
h__h2_ext_cap_heat_cap_rated
10250 W
h__h1_half_cap_heat_cap_rated
5800 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
360 W
c__t1_min_cap_cooling_cap_rated
3110 W
c__low_temp_full_cap_power_rated
2924.8 W
c__low_temp_half_cap_power_rated
820 W
c__t1_half_cap_cooling_cap_rated
5500 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2670 W
c__low_temp_full_cap_cooling_cap_rated
11308.5 W
c__low_temp_half_cap_cooling_cap_rated
5400 W

Australian GEMS registration details

Registration number
AAC6325
GEMS registration id
142598
Status
approved, available (self-reported)
Registration expires
28 October 2026
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.