Australia Β· costs in AUD

Reverse cycle fixed air conditioner
Daikin 4MXM80R2VMA Air Conditioner
Daikin 4MXM80R2VMA is a 8 kW reverse cycle fixed air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC6759).
- Energy rating (cooling)
- 2.5
- Heating: 3
- Annual electricity use
- 1,846 kWh
- 713 cooling + 1,133 heating
- Estimated running cost
- $591 / year
- $49 / month Β· $5,907 over 10 years
- Capacity
- 8 kW cooling
- 9.6 kW heating
About the same electricity as the median of 6 comparable 8 kW reverse cycle fixed registrations (1,846 kWh a year) in the mixed zone. Uses less than 33% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 53% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Daikin 4MXM80R2VMA running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 3,740 | $1,197 | $11,968 |
| Mixed zone | 1,846 | $591 | $5,907 |
| Hot zone | 2,184 | $699 | $6,989 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 8 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Haier 4U71S2PR1FA7.1 kW heating7.1 kW cooling1,445 kWh/yr | 3 | $462 | |
| Rinnai MON3H07B1LA7.3 kW heating7.2 kW cooling1,455 kWh/yr | 3.5 | $466 | |
| Actron Air MRC-071AS-37.8 kW heating7.1 kW cooling1,605 kWh/yr | 3 | $514 | |
| Braemar NCHV07D13B8.3 kW heating7.3 kW cooling1,644 kWh/yr | 3 | $526 | |
| Haier 4U80S2PR1FA8 kW heating8 kW cooling1,652 kWh/yr | 3 | $529 |
Air conditioners similar to the Daikin 4MXM80R2VMA
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Haier 4U80S2PR1FA8.8 kW heating8 kW cooling2,336 kWh/yr | 2 | $748 | |
| Haier 4U80S2PR1FA8 kW heating8 kW cooling1,652 kWh/yr | 3 | $529 | |
| Braemar NCHV08D14B8.8 kW heating8.2 kW cooling1,721 kWh/yr | 3.5 | $551 | |
| Hitachi RAM-G85N5HCE10 kW heating8.5 kW cooling1,984 kWh/yr | 3.5 | $635 | |
| Braemar NCHV07D13B8.3 kW heating7.3 kW cooling1,644 kWh/yr | 3 | $526 | |
| Rinnai MON3H07B1LA7.3 kW heating7.2 kW cooling1,455 kWh/yr | 3.5 | $466 | |
| Actron Air MRC-071AS-37.8 kW heating7.1 kW cooling1,605 kWh/yr | 3 | $514 |
Other Daikin models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin 4MXM80RVMA9.6 kW heating8 kW cooling1,846 kWh/yr | 2.5 | $591 |
Compare 4MXM80R2VMA with another model
Daikin 4MXM80R2VMA specifications
- Type
- Reverse cycle
- Configuration
- Fixed
- Air distribution
- Ducted or non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 8.00 kW
- Cooling power input
- 2.05 kW
- Rated heating capacity (7 Β°C)
- 9.60 kW
- Heating power input
- 2.28 kW
- EER, full load (tested)
- 4.32
- COP, full load (tested)
- 4.81
- Rated AEER
- 3.81
- Rated ACOP
- 4.12
- Standby power (PIA)
- 15.3 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- 60 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- Thailand
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Daikin 4MXM80R2VMA zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 971 | 985 |
| Coldresidential | residential | 3.0 | 2.0 | 463 | 3,277 |
| Mixedcommercial | commercial | β | β | 1,216 | 492 |
| Mixedresidential | residential | 2.5 | 3.0 | 713 | 1,133 |
| Hotcommercial | commercial | β | β | 2,672 | 117 |
| Hotresidential | residential | 3.5 | 4.0 | 2,008 | 176 |
Part-load test points (16 values)
- h__h2_ext_cap_power_rated
- 2620 W
- c__t1_half_cap_power_rated
- 750 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 750 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 7500 W
- h__h1_half_cap_heat_cap_rated
- 4800 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 4000 W
- c__low_temp_have_half_cap_results
- No
Australian GEMS registration details
- Registration number
- AAC6759
- GEMS registration id
- 147079
- Status
- approved, available (self-reported)
- Registration expires
- 30 May 2027
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.4:2012
- MEPS
- 2019
- Product class
- Class 19
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: daikin.com.au. How the derived figures are calculated.