Australia Β· costs in AUD

Reverse cycle split system air conditioner
Fujitsu AOTG36LATL/ARTG36LHTA Air Conditioner
Fujitsu AOTG36LATL/ARTG36LHTA is a 10.5 kW reverse cycle ducted split system air conditioner registered under Australiaβs Energy Rating (GEMS) scheme (registration AAC8698).
- Energy rating (cooling)
- 2.5
- Heating: 2.5
- Annual electricity use
- 2,709 kWh
- 1,051 cooling + 1,658 heating
- Estimated running cost
- $867 / year
- $72 / month Β· $8,669 over 10 years
- Capacity
- 10.5 kW cooling
- 12.1 kW heating
12% more electricity than the median of 129 comparable 10 kW reverse cycle ducted split system registrations (2,429 kWh a year) in the mixed zone. Uses less than 21% of them.
Across all 3,680 air conditioner registrations sold in Australia, it uses less than 40% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ 32c/kWh in AUD; change the price above to your tariff.
Fujitsu AOTG36LATL running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 5,132 | $1,642 | $16,422 |
| Mixed zone | 2,709 | $867 | $8,669 |
| Hot zone | 3,326 | $1,064 | $10,643 |
At 32c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Air conditioners that use less electricity
Same configuration and type, cooling capacity within 12% of 10.5 kW, at least 3% lower annual kWh in the mixed zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-100PZ4R8 / S-100PE4*10 kW heating10 kW cooling1,449 kWh/yr | 2.5 | $464 | |
| Panasonic U-100PZ4R8 / S-100PE4RN10 kW heating10 kW cooling1,449 kWh/yr | 2.5 | $464 | |
| Brivis AONSR13B1/AINHU11B111.3 kW heating10.3 kW cooling1,881 kWh/yr | 4.5 | $602 | |
| Midea UCMI105OB/DUCMI105IHB11 kW heating10 kW cooling2,120 kWh/yr | 4 | $678 | |
| Midea UCMI90OB/DUCMI90IB11 kW heating10.5 kW cooling2,122 kWh/yr | 4 | $679 |
Air conditioners similar to the Fujitsu AOTG36LATL
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Aurora AU-BS36HR-2A-O / AU-LCF36-2A-I11.5 kW heating10.5 kW cooling2,151 kWh/yr | 4 | $688 | |
| Actron Air LRC-100CS / LRE-100CS11.5 kW heating10.5 kW cooling2,126 kWh/yr | 4 | $680 | |
| Mdv C-UV-105N8-QC3W / CDV-105HN8-QC3W11 kW heating10.5 kW cooling2,126 kWh/yr | 4 | $680 | |
| Rinnai DONSR11B1/DINLR11B111.5 kW heating10.5 kW cooling2,165 kWh/yr | 4 | $693 | |
| Mdv C-UV-105N8-QC3W / CDV-105A6N8-QC3W11 kW heating10.5 kW cooling2,135 kWh/yr | 4 | $683 | |
| Rinnai DONSR11B1/DINLR11B111.5 kW heating10.5 kW cooling2,164 kWh/yr | 4 | $692 | |
| Midea UCMI90OB/DUCMI90IB11 kW heating10.5 kW cooling2,122 kWh/yr | 4 | $679 | |
| Kaden KDI36 / KDI3611.5 kW heating10.5 kW cooling2,174 kWh/yr | 4 | $696 |
Compare AOTG36LATL/ARTG36LHTA with another model
Fujitsu AOTG36LATL specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 10.50 kW
- Cooling power input
- 3.18 kW
- Rated heating capacity (7 Β°C)
- 12.10 kW
- Heating power input
- 3.30 kW
- EER, full load (tested)
- 3.37
- COP, full load (tested)
- 3.74
- Rated AEER
- 3.28
- Rated ACOP
- 3.64
- Standby power (PIA)
- 7.6 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R410A
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- No
- Dimensions (WΓHΓD)
- 1050 Γ 400 Γ 500 mm
- Country of manufacture
- Thailand
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Fujitsu AOTG36LATL zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,474 | 1,417 |
| Coldresidential | residential | 2.5 | 2.0 | 670 | 4,462 |
| Mixedcommercial | commercial | β | β | 1,856 | 737 |
| Mixedresidential | residential | 2.5 | 2.5 | 1,051 | 1,658 |
| Hotcommercial | commercial | β | β | 4,134 | 157 |
| Hotresidential | residential | 2.5 | 2.5 | 3,080 | 246 |
Part-load test points (16 values)
- h__h2_ext_cap_power_rated
- 3900 W
- c__t1_half_cap_power_rated
- 1180 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 1240 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 10900 W
- h__h1_half_cap_heat_cap_rated
- 6050 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 5250 W
- c__low_temp_have_half_cap_results
- No
Australian GEMS registration details
- Registration number
- AAC8698
- GEMS registration id
- 167875
- Status
- approved, available (self-reported)
- Registration expires
- 31 March 2030
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 11
Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. Manufacturer: fujitsugeneral.com.au. How the derived figures are calculated.