c/kWh
Energy rating (cooling)
2
Heating: 3
Annual electricity use
664 kWh
250 cooling + 414 heating
Estimated running cost
$212 / year
$18 / month Β· $2,125 over 10 years
Capacity
2.5 kW cooling
3.2 kW heating

22% more electricity than the median of 191 comparable 2.5 kW reverse cycle split system registrations (543 kWh a year) in the mixed zone. Uses less than 8% of them.

Across all 3,680 air conditioner registrations sold in Australia, it uses less than 87% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the mixed zone (Richmond NSW climate: Sydney, Melbourne, Adelaide, Perth). Mixed climate zone shown by default (Sydney, Melbourne, Adelaide, Perth); switch to cold or hot. Cost = kWh Γ— 32c/kWh in AUD; change the price above to your tariff.

Panasonic U-25PZ3R5 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,232$394$3,942
Mixed zone 664$212$2,125
Hot zone 718$230$2,298

At 32c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Air conditioners that use less electricity

Same configuration and type, cooling capacity within 12% of 2.5 kW, at least 3% lower annual kWh in the mixed zone.

ModelStarsEst. cost / yrCompare
Daikin RXM20AVMA / FTXM20AVMA2.7 kW heating2.2 kW cooling380 kWh/yr5.5$122
Midea MFEP26VB-W/MFEP26VB-N2.7 kW heating2.6 kW cooling404 kWh/yr6.5$129
Actron Air WRC-026DS / WRE-026DS2.7 kW heating2.6 kW cooling404 kWh/yr6.5$129
Midea MFEP26VA-W/MFEP26VA-N2.7 kW heating2.6 kW cooling405 kWh/yr6.5$130
Actron Air WRC-026CS / WRE-026CS2.8 kW heating2.6 kW cooling410 kWh/yr6.5$131

Air conditioners similar to the Panasonic U-25PZ3R5

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hitachi RAC-VJ25NHAE/RAI-VJ25RHAE3.5 kW heating2.5 kW cooling450 kWh/yr1$144
Pioneer International HPR-09A22.6 kW heating2.5 kW cooling418 kWh/yr4$134
Carrier 42QHG026N8PB/38QUH026N8PB2.8 kW heating2.5 kW cooling463 kWh/yr5$148
Rinnai HONRTX25/HINRTX252.8 kW heating2.5 kW cooling463 kWh/yr5$148
Daikin RXM25AVMA / FTXM25AVMA3.2 kW heating2.5 kW cooling446 kWh/yr5.5$143
Kaden KSI-2.52.8 kW heating2.5 kW cooling463 kWh/yr5$148
Carrier 38QAF026N8/42QAF026N82.8 kW heating2.5 kW cooling463 kWh/yr5$148
Midea MFAG26VB-W/MFAG26VB-N2.8 kW heating2.5 kW cooling463 kWh/yr5$148

Compare U-25PZ3R5/S-25PY3E with another model

Panasonic U-25PZ3R5 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Cassette
Rated cooling capacity (35 Β°C)
2.50 kW
Cooling power input
0.56 kW
Rated heating capacity (7 Β°C)
3.20 kW
Heating power input
0.72 kW
EER, full load (tested)
4.53
COP, full load (tested)
4.64
Rated AEER
4.19
Rated ACOP
4.23
Standby power (PIA)
11.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Dimensions (WΓ—HΓ—D)
840 Γ— 256 Γ— 840 mm
Country of manufacture
Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-25PZ3R5 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––349355
Coldresidential2.02.51671,065
Mixedcommercial––433195
Mixedresidential2.03.0250414
Hotcommercial––85156
Hotresidential3.03.063781
Part-load test points (20 values)
h__h1_min_cap_power_rated
250 W
c__t1_half_cap_power_rated
270 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
290 W
h__h1_have_min_cap_results
Yes
h__h2_full_cap_power_rated
1160 W
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1300 W
h__h1_half_cap_heat_cap_rated
1600 W
h__h2_full_cap_heat_cap_rated
3330 W
h__h2_is_capable_extended_load
No
c__low_temp_min_cap_power_rated
270 W
c__low_temp_half_cap_power_rated
220 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
1370 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
1370 W
c__low_temp_half_cap_cooling_cap_rated
1450 W

Australian GEMS registration details

Registration number
AAC10455
GEMS registration id
182217
Status
approved, available (self-reported)
Registration expires
10 November 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8

Source: Australian Government Energy Rating (GEMS) registration data, DCCEEW via data.gov.au (CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.