c/kWh
Energy rating (cooling)
4
Heating: 2
Annual electricity use
5,095 kWh
632 cooling + 4,463 heating
Estimated running cost
$1,681 / year
$140 / month Β· $16,814 over 10 years
Capacity
12.9 kW cooling
13.3 kW heating

14% less electricity than the median of 81 comparable 12.5 kW reverse cycle split system registrations (5,949 kWh a year) in the cold zone. Uses less than 84% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 38% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Actron Air URC-125DS running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,095$1,681$16,814
Mixed zone 2,666$880$8,798
Hot zone 3,103$1,024$10,240

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 12.9 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-125PZ4R5 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Panasonic U-125PZ4R8 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528

Heat pumps similar to the Actron Air URC-125DS

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Midea UCMI125OC/CASMI125IC13.3 kW heating12.9 kW cooling5,095 kWh/yr4$1,681
Fujitsu AOTG54KBTA/AUTG54KRLA16 kW heating13 kW cooling7,210 kWh/yr2.5$2,379
Braemar KCHV125D1B/KBHV125D1S13.5 kW heating12.8 kW cooling6,173 kWh/yr3$2,037
Mdv C-UV-125N8-QC3W / CSV-125N8-QC3W13 kW heating12.5 kW cooling5,013 kWh/yr4$1,654
Panasonic U-125PZ4R8 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Daikin RZAV125FV1 / FCTA125AVMA15 kW heating12.5 kW cooling5,020 kWh/yr4$1,657
Panasonic U-125PZ4R5 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Kaden KDI42 / KCI4213 kW heating12.5 kW cooling5,013 kWh/yr4$1,654

Compare URC-125DS / CRE-125DS with another model

Actron Air URC-125DS specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Cassette
Rated cooling capacity (35 Β°C)
12.90 kW
Cooling power input
3.71 kW
Rated heating capacity (7 Β°C)
13.30 kW
Heating power input
3.42 kW
EER, full load (tested)
3.49
COP, full load (tested)
3.81
Rated AEER
3.45
Rated ACOP
3.86
Standby power (PIA)
8.2 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
64.8 dB(A)
Outdoor sound power
71 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Actron Air URC-125DS zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––6231,385
Coldresidential4.02.06324,463
Mixedcommercial––1,175719
Mixedresidential3.52.51,0031,663
Hotcommercial––3,096152
Hotresidential4.03.52,865238
Part-load test points (23 values)
c__t1_min_cap_power_rated
985 W
h__h1_min_cap_power_rated
720 W
h__h2_ext_cap_power_rated
4420 W
c__t1_half_cap_power_rated
1735 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1200 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3850 W
h__h2_ext_cap_heat_cap_rated
12900 W
h__h1_half_cap_heat_cap_rated
6240 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
590 W
c__t1_min_cap_cooling_cap_rated
3600 W
c__low_temp_half_cap_power_rated
1060 W
c__t1_half_cap_cooling_cap_rated
6200 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3990 W
c__low_temp_half_cap_cooling_cap_rated
6580 W

New Zealand E3 registration details

Registration number
AAC9027
GEMS registration id
170379
Status
approved, available (self-reported)
Registration expires
22 June 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.