New Zealand Β· costs in NZD

Reverse cycle split system air conditioner, cassette
Actron Air URC-125DS / CRE-125DS Heat Pump
Actron Air URC-125DS / CRE-125DS is a 12.9 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC9027).
- Energy rating (cooling)
- 4
- Heating: 2
- Annual electricity use
- 5,095 kWh
- 632 cooling + 4,463 heating
- Estimated running cost
- $1,681 / year
- $140 / month Β· $16,814 over 10 years
- Capacity
- 12.9 kW cooling
- 13.3 kW heating
14% less electricity than the median of 81 comparable 12.5 kW reverse cycle split system registrations (5,949 kWh a year) in the cold zone. Uses less than 84% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 38% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Actron Air URC-125DS running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 5,095 | $1,681 | $16,814 |
| Mixed zone | 2,666 | $880 | $8,798 |
| Hot zone | 3,103 | $1,024 | $10,240 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 12.9 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-125PZ4R5 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr | 3 | $1,528 | |
| Panasonic U-125PZ4R8 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr | 3 | $1,528 |
Heat pumps similar to the Actron Air URC-125DS
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Midea UCMI125OC/CASMI125IC13.3 kW heating12.9 kW cooling5,095 kWh/yr | 4 | $1,681 | |
| Fujitsu AOTG54KBTA/AUTG54KRLA16 kW heating13 kW cooling7,210 kWh/yr | 2.5 | $2,379 | |
| Braemar KCHV125D1B/KBHV125D1S13.5 kW heating12.8 kW cooling6,173 kWh/yr | 3 | $2,037 | |
| Mdv C-UV-125N8-QC3W / CSV-125N8-QC3W13 kW heating12.5 kW cooling5,013 kWh/yr | 4 | $1,654 | |
| Panasonic U-125PZ4R8 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr | 3 | $1,528 | |
| Daikin RZAV125FV1 / FCTA125AVMA15 kW heating12.5 kW cooling5,020 kWh/yr | 4 | $1,657 | |
| Panasonic U-125PZ4R5 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr | 3 | $1,528 | |
| Kaden KDI42 / KCI4213 kW heating12.5 kW cooling5,013 kWh/yr | 4 | $1,654 |
Compare URC-125DS / CRE-125DS with another model
Actron Air URC-125DS specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Cassette
- Rated cooling capacity (35 Β°C)
- 12.90 kW
- Cooling power input
- 3.71 kW
- Rated heating capacity (7 Β°C)
- 13.30 kW
- Heating power input
- 3.42 kW
- EER, full load (tested)
- 3.49
- COP, full load (tested)
- 3.81
- Rated AEER
- 3.45
- Rated ACOP
- 3.86
- Standby power (PIA)
- 8.2 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 64.8 dB(A)
- Outdoor sound power
- 71 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Actron Air URC-125DS zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 623 | 1,385 |
| Coldresidential | residential | 4.0 | 2.0 | 632 | 4,463 |
| Mixedcommercial | commercial | β | β | 1,175 | 719 |
| Mixedresidential | residential | 3.5 | 2.5 | 1,003 | 1,663 |
| Hotcommercial | commercial | β | β | 3,096 | 152 |
| Hotresidential | residential | 4.0 | 3.5 | 2,865 | 238 |
Part-load test points (23 values)
- c__t1_min_cap_power_rated
- 985 W
- h__h1_min_cap_power_rated
- 720 W
- h__h2_ext_cap_power_rated
- 4420 W
- c__t1_half_cap_power_rated
- 1735 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 1200 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 3850 W
- h__h2_ext_cap_heat_cap_rated
- 12900 W
- h__h1_half_cap_heat_cap_rated
- 6240 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 590 W
- c__t1_min_cap_cooling_cap_rated
- 3600 W
- c__low_temp_half_cap_power_rated
- 1060 W
- c__t1_half_cap_cooling_cap_rated
- 6200 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 3990 W
- c__low_temp_half_cap_cooling_cap_rated
- 6580 W
New Zealand E3 registration details
- Registration number
- AAC9027
- GEMS registration id
- 170379
- Status
- approved, available (self-reported)
- Registration expires
- 22 June 2030
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 11
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: actronair.com.au. How the derived figures are calculated.