c/kWh
Energy rating (cooling)
4
Heating: 2
Annual electricity use
5,095 kWh
632 cooling + 4,463 heating
Estimated running cost
$1,681 / year
$140 / month Β· $16,814 over 10 years
Capacity
12.9 kW cooling
13.3 kW heating

14% less electricity than the median of 81 comparable 12.5 kW reverse cycle split system registrations (5,949 kWh a year) in the cold zone. Uses less than 84% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 38% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Midea UCMI125OC running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,095$1,681$16,814
Mixed zone 2,666$880$8,798
Hot zone 3,103$1,024$10,240

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 12.9 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-125PZ4R8 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Panasonic U-125PZ4R5 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528

Heat pumps similar to the Midea UCMI125OC

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Actron Air URC-125DS / CRE-125DS13.3 kW heating12.9 kW cooling5,095 kWh/yr4$1,681
Braemar KCHV125D1B/KBHV125D1S13.5 kW heating12.8 kW cooling6,173 kWh/yr3$2,037
Fujitsu AOTG54KBTA/AUTG54KRLA16 kW heating13 kW cooling7,210 kWh/yr2.5$2,379
Daikin RZAV125FV1 / FCTA125AVMA15 kW heating12.5 kW cooling5,020 kWh/yr4$1,657
Kaden KDI42 / KCI4213 kW heating12.5 kW cooling5,013 kWh/yr4$1,654
Panasonic U-125PZ4R5 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Panasonic U-125PZ4R8 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Mdv C-UV-125N8-QC3W / CSV-125N8-QC3W13 kW heating12.5 kW cooling5,013 kWh/yr4$1,654

Compare UCMI125OC/CASMI125IC with another model

Midea UCMI125OC specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Cassette
Rated cooling capacity (35 Β°C)
12.90 kW
Cooling power input
3.71 kW
Rated heating capacity (7 Β°C)
13.30 kW
Heating power input
3.42 kW
EER, full load (tested)
3.49
COP, full load (tested)
3.81
Rated AEER
3.45
Rated ACOP
3.86
Standby power (PIA)
8.2 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
64.8 dB(A)
Outdoor sound power
71 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Midea UCMI125OC zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––6231,385
Coldresidential4.02.06324,463
Mixedcommercial––1,175719
Mixedresidential3.52.51,0031,663
Hotcommercial––3,096152
Hotresidential4.03.52,865238
Part-load test points (23 values)
c__t1_min_cap_power_rated
985 W
h__h1_min_cap_power_rated
720 W
h__h2_ext_cap_power_rated
4420 W
c__t1_half_cap_power_rated
1735 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1200 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3850 W
h__h2_ext_cap_heat_cap_rated
12900 W
h__h1_half_cap_heat_cap_rated
6240 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
590 W
c__t1_min_cap_cooling_cap_rated
3600 W
c__low_temp_half_cap_power_rated
1060 W
c__t1_half_cap_cooling_cap_rated
6200 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3990 W
c__low_temp_half_cap_cooling_cap_rated
6580 W

New Zealand E3 registration details

Registration number
AAC9171
GEMS registration id
170222
Status
approved, available (self-reported)
Registration expires
4 August 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.