c/kWh
Energy rating (cooling)
2.5
Heating: 1.5
Annual electricity use
7,210 kWh
810 cooling + 6,400 heating
Estimated running cost
$2,379 / year
$198 / month Β· $23,793 over 10 years
Capacity
13 kW cooling
16 kW heating

21% more electricity than the median of 81 comparable 12.5 kW reverse cycle split system registrations (5,949 kWh a year) in the cold zone. Uses less than 6% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 23% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Fujitsu AOTG54KBTA running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 7,210$2,379$23,793
Mixed zone 3,500$1,155$11,550
Hot zone 4,087$1,349$13,487

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 13 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-125PZ4R5 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Panasonic U-125PZ4R8 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr3$1,528
Mdv C-UV-125N8-QC3W / CSV-125N8-QC3W13 kW heating12.5 kW cooling5,013 kWh/yr4$1,654
Kaden KDI42 / KCI4213 kW heating12.5 kW cooling5,013 kWh/yr4$1,654
Daikin RZAV125FV1 / FCTA125AVMA15 kW heating12.5 kW cooling5,020 kWh/yr4$1,657

Heat pumps similar to the Fujitsu AOTG54KBTA

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Midea UCMI125OC/CASMI125IC13.3 kW heating12.9 kW cooling5,095 kWh/yr4$1,681
Actron Air URC-125DS / CRE-125DS13.3 kW heating12.9 kW cooling5,095 kWh/yr4$1,681
Braemar KCHV125D1B/KBHV125D1S13.5 kW heating12.8 kW cooling6,173 kWh/yr3$2,037
LG UU140WR2 U30/UTN140MA NA015.5 kW heating13.4 kW cooling9,197 kWh/yr1.5$3,035
Mdv C-UV-125N8-QC3W / CSV-125N8-QC3W13 kW heating12.5 kW cooling5,013 kWh/yr4$1,654
Daikin RZAV125FV1 / FCTA125AVMA15 kW heating12.5 kW cooling5,020 kWh/yr4$1,657
Kaden KDI42 / KCI4213 kW heating12.5 kW cooling5,013 kWh/yr4$1,654

Other Fujitsu models of similar capacity

ModelStarsEst. cost / yrCompare
Fujitsu AOTH54KBTA/AUTH54KRTA15.5 kW heating13 kW cooling7,362 kWh/yr3$2,429

Compare AOTG54KBTA/AUTG54KRLA with another model

Fujitsu AOTG54KBTA specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Cassette
Rated cooling capacity (35 Β°C)
13.00 kW
Cooling power input
4.04 kW
Rated heating capacity (7 Β°C)
16.00 kW
Heating power input
4.23 kW
EER, full load (tested)
3.26
COP, full load (tested)
3.86
Rated AEER
3.20
Rated ACOP
3.77
Standby power (PIA)
5.3 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
61 dB(A)
Outdoor sound power
68 dB(A)
Demand response (AS/NZS 4755)
No
Dimensions (WΓ—HΓ—D)
840 Γ— 840 Γ— 288 mm
Country of manufacture
China, Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Fujitsu AOTG54KBTA zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,7871,994
Coldresidential2.51.58106,400
Mixedcommercial––2,262990
Mixedresidential2.52.01,2812,219
Hotcommercial––5,078189
Hotresidential2.53.03,788299
Part-load test points (16 values)
h__h2_ext_cap_power_rated
4200 W
c__t1_half_cap_power_rated
1430 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1560 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
11400 W
h__h1_half_cap_heat_cap_rated
8000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
6500 W
c__low_temp_have_half_cap_results
No

New Zealand E3 registration details

Registration number
AAC8680
GEMS registration id
167895
Status
approved, available (self-reported)
Registration expires
31 March 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. Manufacturer: fujitsugeneral.com.au. How the derived figures are calculated.