New Zealand Β· costs in NZD

Reverse cycle split system air conditioner
Bonaire CRC6960016/CRC6960116 Heat Pump
Bonaire CRC6960016/CRC6960116 is a 15 kW reverse cycle ducted split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC6610).
- Energy rating (cooling)
- 2.5
- Heating: 1
- Annual electricity use
- 9,385 kWh
- 1,012 cooling + 8,373 heating
- Estimated running cost
- $3,097 / year
- $258 / month Β· $30,971 over 10 years
- Capacity
- 15 kW cooling
- 17.5 kW heating
18% more electricity than the median of 71 comparable 16 kW reverse cycle ducted split system registrations (7,959 kWh a year) in the cold zone. Uses less than 10% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 15% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Bonaire CRC6960016 running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 9,385 | $3,097 | $30,971 |
| Mixed zone | 4,645 | $1,533 | $15,329 |
| Hot zone | 5,077 | $1,675 | $16,754 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 15 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RZA160CV1 / FDYAN160AV118 kW heating15.5 kW cooling4,493 kWh/yr | 2 | $1,483 | |
| Brivis AONSR15B1/AINHU15B115.7 kW heating13.6 kW cooling5,308 kWh/yr | 5 | $1,752 | |
| Kaden KDI48 / KDI4814 kW heating14 kW cooling5,394 kWh/yr | 4 | $1,780 | |
| Actron Air URC-140CS / LRE-140CS14.3 kW heating14 kW cooling5,513 kWh/yr | 4 | $1,819 | |
| Panasonic U-140PZ4R8 / S-1014PF3E13.4 kW heating13.4 kW cooling5,530 kWh/yr | 2.5 | $1,825 |
Heat pumps similar to the Bonaire CRC6960016
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Fujitsu AOTG60LATT/ARTG60LHTA18 kW heating15 kW cooling9,269 kWh/yr | 2 | $3,059 | |
| LG UU150WR3 U30/UHN150B7 N7017 kW heating15 kW cooling8,673 kWh/yr | 2.5 | $2,862 | |
| LG UU150WR2 U30/UHN150B7 N7017 kW heating15 kW cooling10,004 kWh/yr | 1.5 | $3,301 | |
| Temperzone OSA 171RLSFH / ISD 171LYX14.9 kW heating14.9 kW cooling8,519 kWh/yr | 1.5 | $2,811 | |
| Actron Air CRV15BT / EVV15BS15 kW heating14.8 kW cooling6,561 kWh/yr | 2.5 | $2,165 | |
| Actron Air CRV15BT / EAA15BS & EFV15BS15 kW heating14.8 kW cooling6,561 kWh/yr | 2.5 | $2,165 | |
| Hisense AUW-140U4RH1/AUD-140UX4RSH117 kW heating14.5 kW cooling6,926 kWh/yr | 3 | $2,286 | |
| Daikin RZA160CV1 / FDYAN160AV118 kW heating15.5 kW cooling4,493 kWh/yr | 2 | $1,483 |
Compare CRC6960016/CRC6960116 with another model
Bonaire CRC6960016 specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 15.00 kW
- Cooling power input
- 4.80 kW
- Rated heating capacity (7 Β°C)
- 17.50 kW
- Heating power input
- 4.90 kW
- EER, full load (tested)
- 3.40
- COP, full load (tested)
- 3.71
- Rated AEER
- 3.10
- Rated ACOP
- 3.55
- Standby power (PIA)
- 10.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Bonaire CRC6960016 zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 2,233 | 2,660 |
| Coldresidential | residential | 2.5 | 1.0 | 1,012 | 8,373 |
| Mixedcommercial | commercial | β | β | 2,813 | 1,306 |
| Mixedresidential | residential | 2.0 | 1.5 | 1,586 | 3,059 |
| Hotcommercial | commercial | β | β | 6,264 | 265 |
| Hotresidential | residential | 2.5 | 2.0 | 4,662 | 415 |
Part-load test points (20 values)
- h__h2_ext_cap_power_rated
- 4200 W
- c__t1_half_cap_power_rated
- 1800 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 2200 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 12000 W
- h__h1_half_cap_heat_cap_rated
- 9000 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_full_cap_power_rated
- 4387.2 W
- c__low_temp_half_cap_power_rated
- 1645.2 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 7525 W
- c__low_temp_have_half_cap_results
- No
- c__low_temp_full_cap_cooling_cap_rated
- 16155 W
- c__low_temp_half_cap_cooling_cap_rated
- 8104.424999999999 W
New Zealand E3 registration details
- Registration number
- AAC6610
- GEMS registration id
- 146012
- Status
- approved, available (self-reported)
- Registration expires
- 11 April 2027
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 11
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: haier.com/cn. How the derived figures are calculated.