c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
4,758 kWh
556 cooling + 4,202 heating
Estimated running cost
$1,570 / year
$131 / month Β· $15,701 over 10 years
Capacity
10.5 kW cooling
12.5 kW heating

About the same electricity as the median of 136 comparable 10 kW reverse cycle ducted split system registrations (4,758 kWh a year) in the cold zone. Uses less than 49% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 41% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Braemar FCHA100D3G running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,758$1,570$15,701
Mixed zone 2,412$796$7,960
Hot zone 2,707$893$8,933

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 10.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-100PZ4R8 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr3$1,199
Panasonic U-100PZ3R5 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr3$1,199
Brivis AONSR13B1/AINHU11B111.3 kW heating10.3 kW cooling3,713 kWh/yr5$1,225
Midea DUCMI105IB/UCMI105OB11 kW heating10.5 kW cooling4,207 kWh/yr4.5$1,388
Midea UCMI90OB/DUCMI90IB11 kW heating10.5 kW cooling4,207 kWh/yr4.5$1,388

Heat pumps similar to the Braemar FCHA100D3G

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Aurora AU-BS36HR-2A-O / AU-LCF36-2A-I11.5 kW heating10.5 kW cooling4,349 kWh/yr4.5$1,435
Actron Air LRC-100CS / LRE-100CS11.5 kW heating10.5 kW cooling4,311 kWh/yr4.5$1,423
Rinnai DONSR11B1/DINLR11B111.5 kW heating10.5 kW cooling4,404 kWh/yr4.5$1,453
Midea DUCMI105IB/UCMI105OB11 kW heating10.5 kW cooling4,207 kWh/yr4.5$1,388
Mdv C-UV-105N8-QC3W / CDV-105A6N8-QC3W11 kW heating10.5 kW cooling4,253 kWh/yr4.5$1,403
Mdv C-UV-105N8-QC3W / CDV-105HN8-QC3W11 kW heating10.5 kW cooling4,244 kWh/yr4.5$1,401
Rinnai DONSR11B1/DINLR11B111.5 kW heating10.5 kW cooling4,403 kWh/yr4.5$1,453
Midea UCMI90OB/DUCMI90IB11 kW heating10.5 kW cooling4,207 kWh/yr4.5$1,388

Compare FCHA100D3G/FDHA100D1S with another model

Braemar FCHA100D3G specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
10.50 kW
Cooling power input
2.48 kW
Rated heating capacity (7 Β°C)
12.50 kW
Heating power input
2.90 kW
EER, full load (tested)
4.30
COP, full load (tested)
4.37
Rated AEER
4.18
Rated ACOP
4.26
Standby power (PIA)
10.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
69.7 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Braemar FCHA100D3G zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,0441,350
Coldresidential3.52.05564,202
Mixedcommercial––1,395702
Mixedresidential3.52.58571,555
Hotcommercial––3,168156
Hotresidential4.03.02,466241
Part-load test points (18 values)
h__h2_ext_cap_power_rated
4250 W
c__t1_half_cap_power_rated
1160 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1210 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
11800 W
h__h1_half_cap_heat_cap_rated
6400 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
900 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
5400 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
5500 W

New Zealand E3 registration details

Registration number
AAC10418
GEMS registration id
181803
Status
approved, available (self-reported)
Registration expires
19 August 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: seeleyinternational.com. How the derived figures are calculated.