New Zealand Β· costs in NZD

Reverse cycle air conditioner
Braemar MCMX100D105B Heat Pump
Braemar MCMX100D105B is a 10 kW reverse cycle heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC9834).
- Energy rating (cooling)
- 1
- Heating: 1
- Annual electricity use
- 6,677 kWh
- 910 cooling + 5,767 heating
- Estimated running cost
- $2,203 / year
- $184 / month Β· $22,034 over 10 years
- Capacity
- 10 kW cooling
- 11 kW heating
69% more electricity than the median of 20 comparable 10 kW reverse cycle registrations (3,944 kWh a year) in the cold zone. Uses less than 0% of them.
Across all 3,566 air conditioner registrations sold in Australia, it uses less than 27% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Braemar MCMX100D105B running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 6,677 | $2,203 | $22,034 |
| Mixed zone | 3,627 | $1,197 | $11,969 |
| Hot zone | 4,115 | $1,358 | $13,580 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 10 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Rinnai MON4H09B9.3 kW heating9 kW cooling3,457 kWh/yr | 4 | $1,141 | |
| Rinnai MON4H09BNZ9.4 kW heating9 kW cooling3,521 kWh/yr | 4 | $1,162 | |
| Mitsubishi Electric PUMY-SP80YKMD3-A10 kW heating9 kW cooling3,667 kWh/yr | 2 | $1,210 | |
| Mitsubishi Electric PUMY-SP80VKMD3-A10 kW heating9 kW cooling3,667 kWh/yr | 2 | $1,210 | |
| Daikin RSUYA4AVM12.5 kW heating11.2 kW cooling3,675 kWh/yr | 3 | $1,213 |
Heat pumps similar to the Braemar MCMX100D105B
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Hitachi RAM-G110N5HCE12 kW heating10 kW cooling4,580 kWh/yr | 4 | $1,511 | |
| Daikin 5MXM100R2VMA11 kW heating10 kW cooling4,337 kWh/yr | 3 | $1,431 | |
| Haier 5U100S2PS1FA10 kW heating10 kW cooling4,081 kWh/yr | 3.5 | $1,347 | |
| Midea MDV-V98WN8(AUV)14 kW heating9.8 kW cooling4,472 kWh/yr | 3.5 | $1,476 | |
| Rinnai MON4H09B9.6 kW heating9.2 kW cooling3,582 kWh/yr | 4 | $1,182 | |
| Rinnai MON4H09B9.3 kW heating9 kW cooling3,457 kWh/yr | 4 | $1,141 |
Other Braemar models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Braemar NCHV10D1410.5 kW heating10.1 kW cooling4,344 kWh/yr | 3 | $1,434 | |
| Braemar NCHV10D14B11.4 kW heating10.6 kW cooling4,364 kWh/yr | 3.5 | $1,440 |
Compare MCMX100D105B with another model
Braemar MCMX100D105B specifications
- Type
- Reverse cycle
- Configuration
- β
- Air distribution
- Ducted or non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 10.00 kW
- Cooling power input
- β
- Rated heating capacity (7 Β°C)
- 11.00 kW
- Heating power input
- β
- EER, full load (tested)
- 3.25
- COP, full load (tested)
- 3.52
- Rated AEER
- 3.09
- Rated ACOP
- 3.51
- Standby power (PIA)
- 40.4 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R410A
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- 65.3 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Braemar MCMX100D105B zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,939 | 1,891 |
| Coldresidential | residential | 1.0 | 1.0 | 910 | 5,767 |
| Mixedcommercial | commercial | β | β | 2,377 | 1,039 |
| Mixedresidential | residential | 1.0 | 1.0 | 1,354 | 2,273 |
| Hotcommercial | commercial | β | β | 5,006 | 270 |
| Hotresidential | residential | 1.5 | 1.5 | 3,713 | 402 |
Part-load test points (14 values)
- c__t1_half_cap_power_rated
- 1550 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 1650 W
- h__h1_have_min_cap_results
- No
- h__h2_full_cap_power_rated
- 3500 W
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_half_cap_heat_cap_rated
- 5500 W
- h__h2_full_cap_heat_cap_rated
- 8000 W
- h__h2_is_capable_extended_load
- No
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 5000 W
- c__low_temp_have_half_cap_results
- No
New Zealand E3 registration details
- Registration number
- AAC9834
- GEMS registration id
- β
- Status
- approved
- Registration expires
- 9 February 2031
- Registered for sale in
- Australia, New Zealand
- Family
- β
- Regulatory standard
- Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.4:2012
- MEPS
- 2019
- Product class
- 20
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. Manufacturer: seeleyinternational.com. How the derived figures are calculated.