c/kWh
Energy rating (cooling)
1
Heating: 1
Annual electricity use
6,677 kWh
910 cooling + 5,767 heating
Estimated running cost
$2,203 / year
$184 / month Β· $22,034 over 10 years
Capacity
10 kW cooling
11 kW heating

69% more electricity than the median of 20 comparable 10 kW reverse cycle registrations (3,944 kWh a year) in the cold zone. Uses less than 0% of them.

Across all 3,566 air conditioner registrations sold in Australia, it uses less than 27% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Braemar MCMX100D105B running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 6,677$2,203$22,034
Mixed zone 3,627$1,197$11,969
Hot zone 4,115$1,358$13,580

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 10 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Rinnai MON4H09B9.3 kW heating9 kW cooling3,457 kWh/yr4$1,141
Rinnai MON4H09BNZ9.4 kW heating9 kW cooling3,521 kWh/yr4$1,162
Mitsubishi Electric PUMY-SP80YKMD3-A10 kW heating9 kW cooling3,667 kWh/yr2$1,210
Mitsubishi Electric PUMY-SP80VKMD3-A10 kW heating9 kW cooling3,667 kWh/yr2$1,210
Daikin RSUYA4AVM12.5 kW heating11.2 kW cooling3,675 kWh/yr3$1,213

Heat pumps similar to the Braemar MCMX100D105B

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hitachi RAM-G110N5HCE12 kW heating10 kW cooling4,580 kWh/yr4$1,511
Daikin 5MXM100R2VMA11 kW heating10 kW cooling4,337 kWh/yr3$1,431
Haier 5U100S2PS1FA10 kW heating10 kW cooling4,081 kWh/yr3.5$1,347
Midea MDV-V98WN8(AUV)14 kW heating9.8 kW cooling4,472 kWh/yr3.5$1,476
Rinnai MON4H09B9.6 kW heating9.2 kW cooling3,582 kWh/yr4$1,182
Rinnai MON4H09B9.3 kW heating9 kW cooling3,457 kWh/yr4$1,141

Other Braemar models of similar capacity

ModelStarsEst. cost / yrCompare
Braemar NCHV10D1410.5 kW heating10.1 kW cooling4,344 kWh/yr3$1,434
Braemar NCHV10D14B11.4 kW heating10.6 kW cooling4,364 kWh/yr3.5$1,440

Compare MCMX100D105B with another model

Braemar MCMX100D105B specifications

Type
Reverse cycle
Configuration
–
Air distribution
Ducted or non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
10.00 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
11.00 kW
Heating power input
–
EER, full load (tested)
3.25
COP, full load (tested)
3.52
Rated AEER
3.09
Rated ACOP
3.51
Standby power (PIA)
40.4 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
65.3 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Braemar MCMX100D105B zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,9391,891
Coldresidential1.01.09105,767
Mixedcommercial––2,3771,039
Mixedresidential1.01.01,3542,273
Hotcommercial––5,006270
Hotresidential1.51.53,713402
Part-load test points (14 values)
c__t1_half_cap_power_rated
1550 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1650 W
h__h1_have_min_cap_results
No
h__h2_full_cap_power_rated
3500 W
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_half_cap_heat_cap_rated
5500 W
h__h2_full_cap_heat_cap_rated
8000 W
h__h2_is_capable_extended_load
No
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
5000 W
c__low_temp_have_half_cap_results
No

New Zealand E3 registration details

Registration number
AAC9834
GEMS registration id
–
Status
approved
Registration expires
9 February 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
20