c/kWh
Energy rating (cooling)
4
Heating: 2
Annual electricity use
4,580 kWh
498 cooling + 4,082 heating
Estimated running cost
$1,511 / year
$126 / month Β· $15,114 over 10 years
Capacity
10 kW cooling
12 kW heating

5% more electricity than the median of 9 comparable 10 kW reverse cycle fixed registrations (4,344 kWh a year) in the cold zone. Uses less than 11% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 42% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Hitachi RAM-G110N5HCE running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,580$1,511$15,114
Mixed zone 2,226$735$7,346
Hot zone 2,576$850$8,501

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 10 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Rinnai MON4H09B9.3 kW heating9 kW cooling3,457 kWh/yr4$1,141
Rinnai MON4H09B1LA9.5 kW heating9 kW cooling3,592 kWh/yr4$1,185
Haier 5U100S2PS1FA10 kW heating10 kW cooling4,081 kWh/yr3.5$1,347
Daikin 5MXM100R2VMA11 kW heating10 kW cooling4,337 kWh/yr3$1,431
Braemar NCHV10D1410.5 kW heating10.1 kW cooling4,344 kWh/yr3$1,434

Heat pumps similar to the Hitachi RAM-G110N5HCE

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Haier 5U100S2PS1FA10 kW heating10 kW cooling4,081 kWh/yr3.5$1,347
Haier 5U100S2PS1FA10 kW heating10 kW cooling4,916 kWh/yr2.5$1,622
Daikin 5MXM100R2VMA11 kW heating10 kW cooling4,337 kWh/yr3$1,431
Braemar NCHV10D1410.5 kW heating10.1 kW cooling4,344 kWh/yr3$1,434
Braemar NCHV10D1410.8 kW heating10.4 kW cooling4,473 kWh/yr3$1,476
Rinnai MON4H09B9.3 kW heating9 kW cooling3,457 kWh/yr4$1,141
Rinnai MON4H09B1LA9.5 kW heating9 kW cooling3,592 kWh/yr4$1,185

Compare RAM-G110N5HCE with another model

Hitachi RAM-G110N5HCE specifications

Type
Reverse cycle
Configuration
Fixed
Air distribution
Ducted or non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
10.00 kW
Cooling power input
0.00 kW
Rated heating capacity (7 Β°C)
12.00 kW
Heating power input
0.00 kW
EER, full load (tested)
3.82
COP, full load (tested)
4.56
Rated AEER
3.36
Rated ACOP
4.31
Standby power (PIA)
2.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
70 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Hitachi RAM-G110N5HCE zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––9531,251
Coldresidential4.02.04984,082
Mixedcommercial––1,294617
Mixedresidential3.53.08101,416
Hotcommercial––3,038122
Hotresidential3.53.52,382194
Part-load test points (18 values)
h__h2_ext_cap_power_rated
3300 W
c__t1_half_cap_power_rated
960 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1030 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
9600 W
h__h1_half_cap_heat_cap_rated
6000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
780 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
5000 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
5385 W

New Zealand E3 registration details

Registration number
AAC9701
GEMS registration id
164457
Status
approved, available (self-reported)
Registration expires
29 December 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 20

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: temperzone.com. How the derived figures are calculated.