c/kWh
Energy rating (cooling)
3.5
Heating: 3
Annual electricity use
4,472 kWh
453 cooling + 4,019 heating
Estimated running cost
$1,476 / year
$123 / month Β· $14,758 over 10 years
Capacity
9.8 kW cooling
14 kW heating

13% more electricity than the median of 20 comparable 10 kW reverse cycle registrations (3,944 kWh a year) in the cold zone. Uses less than 25% of them.

Across all 3,566 air conditioner registrations sold in Australia, it uses less than 44% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Midea MDV-V98WN8(AUV) running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,472$1,476$14,758
Mixed zone 2,255$744$7,442
Hot zone 2,108$696$6,956

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 9.8 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Rinnai MON4H09B9.3 kW heating9 kW cooling3,457 kWh/yr4$1,141
Rinnai MON4H09BNZ9.4 kW heating9 kW cooling3,521 kWh/yr4$1,162
Mitsubishi Electric PUMY-SP80VKMD3-A-BS10 kW heating9 kW cooling3,667 kWh/yr2$1,210
Mitsubishi Electric PUMY-SP80YKMD3-A-BS10 kW heating9 kW cooling3,667 kWh/yr2$1,210
Mitsubishi Heavy Industries FDCS90KXZEN1-W9 kW heating9 kW cooling3,795 kWh/yr2.5$1,252

Heat pumps similar to the Midea MDV-V98WN8(AUV)

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hitachi RAM-G110N5HCE12 kW heating10 kW cooling4,580 kWh/yr4$1,511
Daikin 5MXM100R2VMA11 kW heating10 kW cooling4,337 kWh/yr3$1,431
Haier 5U100S2PS1FA10 kW heating10 kW cooling4,081 kWh/yr3.5$1,347
Braemar MCMX100D105B11 kW heating10 kW cooling6,677 kWh/yr1$2,203
Braemar NCHV10D1410.5 kW heating10.1 kW cooling4,344 kWh/yr3$1,434
Rinnai MON4H09B9.6 kW heating9.2 kW cooling3,582 kWh/yr4$1,182
Rinnai MON4H09B9.3 kW heating9 kW cooling3,457 kWh/yr4$1,141
Mitsubishi Electric PUMY-SP80VKMD3-A-BS10 kW heating9 kW cooling3,667 kWh/yr2$1,210

Compare MDV-V98WN8(AUV) with another model

Midea MDV-V98WN8(AUV) specifications

Type
Reverse cycle
Configuration
–
Air distribution
Ducted or non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
9.80 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
14.00 kW
Heating power input
–
EER, full load (tested)
5.06
COP, full load (tested)
4.91
Rated AEER
4.84
Rated ACOP
4.77
Standby power (PIA)
25.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
71 dB(A)
Demand response (AS/NZS 4755)
–
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Midea MDV-V98WN8(AUV) zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––7711,323
Coldresidential3.53.04534,019
Mixedcommercial––1,027718
Mixedresidential3.53.56871,568
Hotcommercial––2,280184
Hotresidential5.04.01,833275
Part-load test points (23 values)
c__t1_min_cap_power_rated
767 W
h__h1_min_cap_power_rated
1151 W
h__h2_ext_cap_power_rated
6087 W
c__t1_half_cap_power_rated
810 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1205 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
6940 W
h__h2_ext_cap_heat_cap_rated
16800 W
h__h1_half_cap_heat_cap_rated
7000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
602 W
c__t1_min_cap_cooling_cap_rated
4640 W
c__low_temp_half_cap_power_rated
608 W
c__t1_half_cap_cooling_cap_rated
4900 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
5000 W
c__low_temp_half_cap_cooling_cap_rated
5075 W

New Zealand E3 registration details

Registration number
AAC817225361
GEMS registration id
–
Status
approved
Registration expires
19 October 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
19

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 28 October 2026; last checked 29 October 2026. How the derived figures are calculated.