c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
2,233 kWh
264 cooling + 1,969 heating
Estimated running cost
$737 / year
$61 / month Β· $7,369 over 10 years
Capacity
5 kW cooling
5.8 kW heating

4% more electricity than the median of 236 comparable 5 kW reverse cycle split system registrations (2,154 kWh a year) in the cold zone. Uses less than 36% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 73% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Daikin RXM50R5V1B running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,233$737$7,369
Mixed zone 1,157$382$3,818
Hot zone 1,276$421$4,211

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling1,543 kWh/yr4.5$509
Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling1,571 kWh/yr4.5$518
Gree GWH15AGDXD-K6DNA1A/O / GWH15AGDXD-K6DNA1A/I4.7 kW heating4.6 kW cooling1,835 kWh/yr4$606
Gree GWH15QDXE-K6DNA1A/O / GWH15QDXE-K6DNC8B/I4.7 kW heating4.6 kW cooling1,839 kWh/yr3$607
Midea MFCA50VA-W/MFCA50VA-N5.2 kW heating5.2 kW cooling1,841 kWh/yr4.5$608

Heat pumps similar to the Daikin RXM50R5V1B

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Panasonic CU-HZ50DKR / CS-HZ50DKR6 kW heating5 kW cooling1,940 kWh/yr5.5$640
Actron Air WRC-050CS / WRE-050CS5 kW heating5 kW cooling1,936 kWh/yr5$639
Toshiba RAV-GP561ATP-A/RAV-GM561UTP-A5.6 kW heating5 kW cooling1,963 kWh/yr4$648
Haier 1U50PFHRA / AS50PFHRA5.3 kW heating5 kW cooling1,973 kWh/yr4$651
Hisense HAWG18KR5.3 kW heating5 kW cooling1,993 kWh/yr4$658
Pioneer International HPR-18A25.1 kW heating5 kW cooling1,968 kWh/yr4$649
Panasonic U-50PZ3R5/S-50PY3E5 kW heating5 kW cooling1,982 kWh/yr2.5$654
Kaden KS185.1 kW heating5 kW cooling2,008 kWh/yr3.5$663

Compare RXM50R5V1B / FVXM50A3V1B9 with another model

Daikin RXM50R5V1B specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Floor mounted
Rated cooling capacity (35 Β°C)
5.00 kW
Cooling power input
1.31 kW
Rated heating capacity (7 Β°C)
5.80 kW
Heating power input
1.52 kW
EER, full load (tested)
3.76
COP, full load (tested)
4.03
Rated AEER
3.75
Rated ACOP
3.76
Standby power (PIA)
6.6 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
61 dB(A)
Outdoor sound power
62 dB(A)
Demand response (AS/NZS 4755)
No
Dimensions (WΓ—HΓ—D)
750 Γ— 600 Γ— 238 mm
Country of manufacture
Czechia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Daikin RXM50R5V1B zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––434629
Coldresidential3.52.02641,969
Mixedcommercial––611332
Mixedresidential3.02.5412745
Hotcommercial––1,42776
Hotresidential4.03.01,160116
Part-load test points (18 values)
h__h2_ext_cap_power_rated
2140 W
c__t1_half_cap_power_rated
565 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
545 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
5935 W
h__h1_half_cap_heat_cap_rated
2900 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
415 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
2500 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
2693 W

Other model numbers on registration ZAC0767

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
ZAC0767
GEMS registration id
143332
Status
approved, available (self-reported)
Registration expires
n/a (NZ registration)
Registered for sale in
New Zealand
Family
RXM50R2V1B
Regulatory standard
[SEER Non Multi-Split <=65kW] (Air Conditioners up to 65kW) EE Regulations 2020 Schedule 2A
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: daikin.co.nz. How the derived figures are calculated.