c/kWh
Energy rating (cooling)
2.5
Heating: 1.5
Annual electricity use
4,928 kWh
619 cooling + 4,309 heating
Estimated running cost
$1,626 / year
$136 / month Β· $16,262 over 10 years
Capacity
10 kW cooling
11.2 kW heating

11% more electricity than the median of 127 comparable 10 kW reverse cycle split system registrations (4,446 kWh a year) in the cold zone. Uses less than 17% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 39% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Daikin RZAV100C2Y1 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,928$1,626$16,262
Mixed zone 2,554$843$8,428
Hot zone 3,033$1,001$10,009

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 10 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RZAC100C2Y1 / FCA100CVMA11.2 kW heating10 kW cooling1,073 kWh/yr2.5$354
Panasonic U-100PZ3R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr3.5$1,114
Panasonic U-100PZ4R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr3.5$1,114
Kogan KASSSAC90HB9.5 kW heating9 kW cooling3,668 kWh/yr3.5$1,210
Kogan KASSSAC90HD9.5 kW heating9 kW cooling3,668 kWh/yr3.5$1,210

Heat pumps similar to the Daikin RZAV100C2Y1

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hitachi PAS-4.0UFASNQ1 / PPK-4.0UFA1NQ11.5 kW heating10 kW cooling4,677 kWh/yr3$1,543
Braemar CCHV100D1S/CSHV100D1S11 kW heating10 kW cooling4,445 kWh/yr3.5$1,467
Gree GWH36AWFXH-K6DNA1A/O / GWH36AWFXH-K6DNA1A/I11 kW heating10 kW cooling4,445 kWh/yr3.5$1,467
Kinghome KWH100ATBXB-K6DNA1/O / KWH100ATBXB-K6DNA1/I11 kW heating10 kW cooling4,445 kWh/yr3.5$1,467
Panasonic U-100PZ3R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr3.5$1,114
Panasonic U-100PZ4R8 / S-1014PU3E10 kW heating10 kW cooling3,376 kWh/yr3.5$1,114
Actron Air URC-100DS / CRE-100DS10.5 kW heating10 kW cooling4,000 kWh/yr3.5$1,320
Midea UCMI105OC/CASMI105IC10.5 kW heating10 kW cooling4,000 kWh/yr3.5$1,320

Compare RZAV100C2Y1 / FAA100BVMA with another model

Daikin RZAV100C2Y1 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
10.00 kW
Cooling power input
3.11 kW
Rated heating capacity (7 Β°C)
11.20 kW
Heating power input
3.48 kW
EER, full load (tested)
3.42
COP, full load (tested)
3.22
Rated AEER
3.16
Rated ACOP
3.17
Standby power (PIA)
14.7 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Daikin RZAV100C2Y1 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,3041,340
Coldresidential2.51.56194,309
Mixedcommercial––1,653690
Mixedresidential2.52.09751,579
Hotcommercial––3,703156
Hotresidential3.03.02,794239
Part-load test points (16 values)
h__h2_ext_cap_power_rated
3700 W
c__t1_half_cap_power_rated
1000 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1100 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
9700 W
h__h1_half_cap_heat_cap_rated
5600 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
5000 W
c__low_temp_have_half_cap_results
No

Other model numbers on registration AAC6470

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC6470
GEMS registration id
144465
Status
approved, available (self-reported)
Registration expires
24 February 2027
Registered for sale in
Australia, New Zealand
Family
RZAV100C2Y1 / FAA100BAVMA
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: daikin.com.au. How the derived figures are calculated.