c/kWh
Energy rating (cooling)
4
Heating: 3
Annual electricity use
1,016 kWh
117 cooling + 899 heating
Estimated running cost
$335 / year
$28 / month Β· $3,353 over 10 years
Capacity
2.5 kW cooling
3.2 kW heating

5% less electricity than the median of 177 comparable 2.5 kW reverse cycle split system registrations (1,073 kWh a year) in the cold zone. Uses less than 64% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 89% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Hitachi RAC-S25YHAB running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,016$335$3,353
Mixed zone 519$171$1,713
Hot zone 584$193$1,927

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 2.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Hitachi RAC-VJ25NHAE/RAI-VJ25RHAE3.5 kW heating2.5 kW cooling653 kWh/yr4$215
Daikin RXM20AVMA / FTXM20AVMA2.7 kW heating2.2 kW cooling725 kWh/yr6$239
Midea MFEP26VA-W/MFEP26VA-N2.7 kW heating2.6 kW cooling776 kWh/yr6.5$256
Actron Air WRC-026DS / WRE-026DS2.7 kW heating2.6 kW cooling790 kWh/yr7$261
Midea MFEP26VB-W/MFEP26VB-N2.7 kW heating2.6 kW cooling790 kWh/yr7$261

Heat pumps similar to the Hitachi RAC-S25YHAB

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Rinnai HSNRTX252.8 kW heating2.5 kW cooling897 kWh/yr5$296
Carrier 38QAF026N8/42QAF026N82.8 kW heating2.5 kW cooling897 kWh/yr5$296
Midea MFAG26VB-W/MFAG26VB-N2.8 kW heating2.5 kW cooling897 kWh/yr5$296
Pioneer International HPR-09A22.6 kW heating2.5 kW cooling845 kWh/yr4$279
Carrier 38QRF026N8/42QRF026N82.8 kW heating2.5 kW cooling897 kWh/yr5$296
Rinnai HONRTX25/HINRTX252.8 kW heating2.5 kW cooling897 kWh/yr5$296
Daikin RXM25AVMA / FTXM25AVMA3.2 kW heating2.5 kW cooling888 kWh/yr6$293
Kaden KSI-2.52.8 kW heating2.5 kW cooling897 kWh/yr5$296

Compare RAC-S25YHAB/RAS-S25YHAB with another model

Hitachi RAC-S25YHAB specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
2.50 kW
Cooling power input
0.49 kW
Rated heating capacity (7 Β°C)
3.20 kW
Heating power input
0.63 kW
EER, full load (tested)
5.10
COP, full load (tested)
5.20
Rated AEER
5.07
Rated ACOP
5.06
Standby power (PIA)
0.8 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
54 dB(A)
Outdoor sound power
61 dB(A)
Demand response (AS/NZS 4755)
Yes (requires additional part)
Dimensions (WΓ—HΓ—D)
780 Γ— 280 Γ— 230 mm
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Hitachi RAC-S25YHAB zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––268291
Coldresidential4.03.0117899
Mixedcommercial––334153
Mixedresidential4.03.5181338
Hotcommercial––72832
Hotresidential4.54.053450
Part-load test points (20 values)
h__h2_ext_cap_power_rated
915 W
c__t1_half_cap_power_rated
240 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
280 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
3200 W
h__h1_half_cap_heat_cap_rated
1700 W
h__h2_is_capable_extended_load
Yes
c__low_temp_full_cap_power_rated
447.86 W
c__low_temp_half_cap_power_rated
219.36 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
1350 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
2692.5 W
c__low_temp_half_cap_cooling_cap_rated
1453.95 W

New Zealand E3 registration details

Registration number
AAC7614
GEMS registration id
154759
Status
approved, available (self-reported)
Registration expires
3 July 2028
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8