New Zealand Β· costs in NZD

Reverse cycle fixed air conditioner
Hyundai HYSMHS10OT* Heat Pump
Hyundai HYSMHS10OT* is a 10.7 kW reverse cycle fixed heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC10193).
- Energy rating (cooling)
- 3
- Heating: 2
- Annual electricity use
- 4,935 kWh
- 590 cooling + 4,345 heating
- Estimated running cost
- $1,629 / year
- $136 / month Β· $16,286 over 10 years
- Capacity
- 10.7 kW cooling
- 12.3 kW heating
9% more electricity than the median of 26 comparable 10 kW reverse cycle fixed registrations (4,539 kWh a year) in the cold zone. Uses less than 15% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 39% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Hyundai HYSMHS10OT* running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 4,935 | $1,629 | $16,286 |
| Mixed zone | 2,538 | $838 | $8,375 |
| Hot zone | 2,898 | $956 | $9,563 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 10.7 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Mitsubishi Electric MXZ-5F100VGD10 kW heating10 kW cooling3,703 kWh/yr | 3.5 | $1,222 | |
| Fujitsu AOTG36LBLA512 kW heating10 kW cooling4,079 kWh/yr | 3.5 | $1,346 | |
| Fujitsu AOTH36KBTA512 kW heating10 kW cooling4,088 kWh/yr | 4 | $1,349 | |
| Daikin 5MXM100RVMA11 kW heating10 kW cooling4,337 kWh/yr | 3 | $1,431 | |
| TECO TSOM106HVAG411.4 kW heating10.6 kW cooling4,364 kWh/yr | 3.5 | $1,440 |
Heat pumps similar to the Hyundai HYSMHS10OT*
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Bonaire H4M105S2AE12.3 kW heating10.7 kW cooling4,935 kWh/yr | 3 | $1,629 | |
| Carrier 38QUM105D8S511 kW heating10.7 kW cooling4,608 kWh/yr | 3 | $1,521 | |
| TECO TSOM106HVAG411.4 kW heating10.6 kW cooling4,364 kWh/yr | 3.5 | $1,440 | |
| TCL FMA-36I4HD/DVO10.5 kW heating10.5 kW cooling5,478 kWh/yr | 2.5 | $1,808 | |
| Midea MULMI0511B/MFAG20N11 kW heating10.5 kW cooling4,722 kWh/yr | 3 | $1,558 | |
| Hisense AMW4-100U4RQA/AST-09UW4RMETD0111.1 kW heating10.5 kW cooling4,380 kWh/yr | 3 | $1,445 | |
| Hisense AMW4-100U4RQA11.1 kW heating10.5 kW cooling4,380 kWh/yr | 3 | $1,445 | |
| Midea MULMI0511B11 kW heating10.5 kW cooling4,536 kWh/yr | 3 | $1,497 |
Compare HYSMHS10OT* with another model
Hyundai HYSMHS10OT* specifications
- Type
- Reverse cycle
- Configuration
- Fixed
- Air distribution
- Non-ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 10.70 kW
- Cooling power input
- 2.75 kW
- Rated heating capacity (7 Β°C)
- 12.30 kW
- Heating power input
- 3.20 kW
- EER, full load (tested)
- 3.80
- COP, full load (tested)
- 3.82
- Rated AEER
- 3.84
- Rated ACOP
- 3.80
- Standby power (PIA)
- 10.0 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- 73.8 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Hyundai HYSMHS10OT* zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,137 | 1,385 |
| Coldresidential | residential | 3.0 | 2.0 | 590 | 4,345 |
| Mixedcommercial | commercial | β | β | 1,506 | 723 |
| Mixedresidential | residential | 3.0 | 2.5 | 917 | 1,621 |
| Hotcommercial | commercial | β | β | 3,431 | 159 |
| Hotresidential | residential | 3.5 | 3.0 | 2,652 | 246 |
Part-load test points (18 values)
- h__h2_ext_cap_power_rated
- 4100 W
- c__t1_half_cap_power_rated
- 1140 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 1200 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 11500 W
- h__h1_half_cap_heat_cap_rated
- 6100 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_half_cap_power_rated
- 900 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 5400 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_half_cap_cooling_cap_rated
- 5400 W
Other model numbers on registration AAC10193
Registered together and sharing the same test results. Usually variants of the same unit.
New Zealand E3 registration details
- Registration number
- AAC10193
- GEMS registration id
- 179984
- Status
- approved, available (self-reported)
- Registration expires
- 1 June 2031
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- HYSMHS10OT*
- Regulatory standard
- [SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.4:2012
- MEPS
- 2019
- Product class
- Class 20
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.