c/kWh
Energy rating (cooling)
3
Heating: 2
Annual electricity use
3,776 kWh
497 cooling + 3,279 heating
Estimated running cost
$1,246 / year
$104 / month Β· $12,461 over 10 years
Capacity
8.8 kW cooling
8.8 kW heating

4% more electricity than the median of 120 comparable 8 kW reverse cycle split system registrations (3,622 kWh a year) in the cold zone. Uses less than 35% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 49% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Hyundai HYSSAC88PWA running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 3,776$1,246$12,461
Mixed zone 1,984$655$6,547
Hot zone 2,479$818$8,181

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 8.8 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Kogan KASSSAC80HE8.2 kW heating8 kW cooling3,283 kWh/yr4.5$1,083
Kogan KASSSAC80H*8.2 kW heating8 kW cooling3,283 kWh/yr4.5$1,083
Comfee CASG-XG80/CASN-XG808.2 kW heating7.9 kW cooling3,328 kWh/yr3.5$1,098
Rinnai HSNRP80B8.3 kW heating7.8 kW cooling3,362 kWh/yr3.5$1,109
Carrier 38QHG080N8-1/42QHG080N8-18.2 kW heating8 kW cooling3,371 kWh/yr3.5$1,112

Heat pumps similar to the Hyundai HYSSAC88PWA

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
TECO TWS-TSO88H3DVJT8.8 kW heating8.8 kW cooling3,776 kWh/yr3$1,246
TECO TWS-TSO88H3DVKT8.8 kW heating8.8 kW cooling3,776 kWh/yr3$1,246
Panasonic CU-RZ95AKR / S-100PK4R9 kW heating8.8 kW cooling3,523 kWh/yr3$1,163
Panasonic U-100PZ3R8/S-100PK3R9 kW heating9 kW cooling3,534 kWh/yr2.5$1,166
LG LS30S0U DX6ALAP/LS30S0N DX6ALAP8.7 kW heating8.6 kW cooling3,679 kWh/yr3$1,214
Kogan KASSSAC90HA9.5 kW heating9 kW cooling3,668 kWh/yr3.5$1,210
Kogan KASSSAC90HF9.5 kW heating9 kW cooling3,668 kWh/yr3.5$1,210
Midea MFAG90VB-W/MFAG90VB-N9.5 kW heating9 kW cooling3,874 kWh/yr4$1,278

Compare HYSSAC88PWA with another model

Hyundai HYSSAC88PWA specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
8.80 kW
Cooling power input
2.50 kW
Rated heating capacity (7 Β°C)
8.80 kW
Heating power input
2.25 kW
EER, full load (tested)
3.62
COP, full load (tested)
4.05
Rated AEER
3.49
Rated ACOP
3.88
Standby power (PIA)
5.4 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
53.9 dB(A)
Outdoor sound power
64 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Hyundai HYSSAC88PWA zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,0701,022
Coldresidential3.02.04973,279
Mixedcommercial––1,360524
Mixedresidential3.02.57841,200
Hotcommercial––3,078110
Hotresidential3.03.02,306173
Part-load test points (18 values)
c__t1_half_cap_power_rated
830 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
840 W
h__h1_have_min_cap_results
No
h__h2_full_cap_power_rated
2700 W
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_half_cap_heat_cap_rated
4250 W
h__h2_full_cap_heat_cap_rated
7500 W
h__h2_is_capable_extended_load
No
c__low_temp_full_cap_power_rated
2285 W
c__low_temp_half_cap_power_rated
740 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
4300 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_full_cap_cooling_cap_rated
9477.6 W
c__low_temp_half_cap_cooling_cap_rated
4500 W

Other model numbers on registration AAC7612

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC7612
GEMS registration id
155155
Status
approved, available (self-reported)
Registration expires
3 July 2028
Registered for sale in
Australia, Fiji, New Zealand
Family
HYSSAC88PW*
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.