New Zealand Β· costs in NZD

Reverse cycle split system air conditioner, wall hung
Hyundai HYSSAC88PWD Heat Pump
Hyundai HYSSAC88PWD is a 8.8 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC7612).
- Energy rating (cooling)
- 3
- Heating: 2
- Annual electricity use
- 3,776 kWh
- 497 cooling + 3,279 heating
- Estimated running cost
- $1,246 / year
- $104 / month Β· $12,461 over 10 years
- Capacity
- 8.8 kW cooling
- 8.8 kW heating
4% more electricity than the median of 120 comparable 8 kW reverse cycle split system registrations (3,622 kWh a year) in the cold zone. Uses less than 35% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 49% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Hyundai HYSSAC88PWD running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 3,776 | $1,246 | $12,461 |
| Mixed zone | 1,984 | $655 | $6,547 |
| Hot zone | 2,479 | $818 | $8,181 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 8.8 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Kogan KASSSAC80H*8.2 kW heating8 kW cooling3,283 kWh/yr | 4.5 | $1,083 | |
| Kogan KASSSAC80HE8.2 kW heating8 kW cooling3,283 kWh/yr | 4.5 | $1,083 | |
| Comfee CASG-XG80/CASN-XG808.2 kW heating7.9 kW cooling3,328 kWh/yr | 3.5 | $1,098 | |
| Rinnai HSNRP80B8.3 kW heating7.8 kW cooling3,362 kWh/yr | 3.5 | $1,109 | |
| Carrier 38QHG080N8-1/42QHG080N8-18.2 kW heating8 kW cooling3,371 kWh/yr | 3.5 | $1,112 |
Heat pumps similar to the Hyundai HYSSAC88PWD
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic CU-RZ95AKR / S-100PK4R9 kW heating8.8 kW cooling3,523 kWh/yr | 3 | $1,163 | |
| TECO TWS-TSO88H3DVKT8.8 kW heating8.8 kW cooling3,776 kWh/yr | 3 | $1,246 | |
| TECO TWS-TSO88H3DVJT8.8 kW heating8.8 kW cooling3,776 kWh/yr | 3 | $1,246 | |
| LG LS30S0U DX6ALAP/LS30S0N DX6ALAP8.7 kW heating8.6 kW cooling3,679 kWh/yr | 3 | $1,214 | |
| Kogan KASSSAC90HF9.5 kW heating9 kW cooling3,668 kWh/yr | 3.5 | $1,210 | |
| Kogan KASSSAC90HA9.5 kW heating9 kW cooling3,668 kWh/yr | 3.5 | $1,210 | |
| Panasonic U-100PZ3R8/S-100PK3R9 kW heating9 kW cooling3,534 kWh/yr | 2.5 | $1,166 | |
| Midea MFAG90VB-W/MFAG90VB-N9.5 kW heating9 kW cooling3,874 kWh/yr | 4 | $1,278 |
Compare HYSSAC88PWD with another model
Hyundai HYSSAC88PWD specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Wall hung
- Rated cooling capacity (35 Β°C)
- 8.80 kW
- Cooling power input
- 2.50 kW
- Rated heating capacity (7 Β°C)
- 8.80 kW
- Heating power input
- 2.25 kW
- EER, full load (tested)
- 3.62
- COP, full load (tested)
- 4.05
- Rated AEER
- 3.49
- Rated ACOP
- 3.88
- Standby power (PIA)
- 5.4 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 53.9 dB(A)
- Outdoor sound power
- 64 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Hyundai HYSSAC88PWD zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,070 | 1,022 |
| Coldresidential | residential | 3.0 | 2.0 | 497 | 3,279 |
| Mixedcommercial | commercial | β | β | 1,360 | 524 |
| Mixedresidential | residential | 3.0 | 2.5 | 784 | 1,200 |
| Hotcommercial | commercial | β | β | 3,078 | 110 |
| Hotresidential | residential | 3.0 | 3.0 | 2,306 | 173 |
Part-load test points (18 values)
- c__t1_half_cap_power_rated
- 830 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 840 W
- h__h1_have_min_cap_results
- No
- h__h2_full_cap_power_rated
- 2700 W
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_half_cap_heat_cap_rated
- 4250 W
- h__h2_full_cap_heat_cap_rated
- 7500 W
- h__h2_is_capable_extended_load
- No
- c__low_temp_full_cap_power_rated
- 2285 W
- c__low_temp_half_cap_power_rated
- 740 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 4300 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_full_cap_cooling_cap_rated
- 9477.6 W
- c__low_temp_half_cap_cooling_cap_rated
- 4500 W
Other model numbers on registration AAC7612
Registered together and sharing the same test results. Usually variants of the same unit.
New Zealand E3 registration details
- Registration number
- AAC7612
- GEMS registration id
- 155155
- Status
- approved, available (self-reported)
- Registration expires
- 3 July 2028
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- HYSSAC88PW*
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 9
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.