c/kWh
Energy rating (cooling)
3.5
Heating: 1.5
Annual electricity use
4,993 kWh
566 cooling + 4,427 heating
Estimated running cost
$1,648 / year
$137 / month Β· $16,477 over 10 years
Capacity
11 kW cooling
11.5 kW heating

10% more electricity than the median of 26 comparable 10 kW reverse cycle fixed registrations (4,539 kWh a year) in the cold zone. Uses less than 12% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 38% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Kaden KM36 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 4,993$1,648$16,477
Mixed zone 2,541$839$8,385
Hot zone 2,712$895$8,950

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 11 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Mitsubishi Electric MXZ-5F100VGD10 kW heating10 kW cooling3,703 kWh/yr3.5$1,222
Fujitsu AOTG36LBLA512 kW heating10 kW cooling4,079 kWh/yr3.5$1,346
Fujitsu AOTH36KBTA512 kW heating10 kW cooling4,088 kWh/yr4$1,349
Daikin 5MXM100RVMA11 kW heating10 kW cooling4,337 kWh/yr3$1,431
TECO TSOM106HVAG411.4 kW heating10.6 kW cooling4,364 kWh/yr3.5$1,440

Heat pumps similar to the Kaden KM36

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hyundai HYSMHS10OT*12.3 kW heating10.7 kW cooling4,935 kWh/yr3$1,629
Carrier 38QUM105D8S511 kW heating10.7 kW cooling4,608 kWh/yr3$1,521
Bonaire H4M105S2AE12.3 kW heating10.7 kW cooling4,935 kWh/yr3$1,629
Hyundai HYSMHS10OTB12.3 kW heating10.7 kW cooling4,935 kWh/yr3$1,629
TECO TSOM106HVAG411.4 kW heating10.6 kW cooling4,364 kWh/yr3.5$1,440
Hisense AMW4-100U4RQA/AST-09UW4RMETD0111.1 kW heating10.5 kW cooling4,380 kWh/yr3$1,445
Hisense AMW4-100U4RQA11.1 kW heating10.5 kW cooling4,380 kWh/yr3$1,445
Midea MULMI0511B11 kW heating10.5 kW cooling4,536 kWh/yr3$1,497

Compare KM36 with another model

Kaden KM36 specifications

Type
Reverse cycle
Configuration
Fixed
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
11.00 kW
Cooling power input
3.15 kW
Rated heating capacity (7 Β°C)
11.50 kW
Heating power input
2.95 kW
EER, full load (tested)
3.47
COP, full load (tested)
3.91
Rated AEER
3.42
Rated ACOP
3.82
Standby power (PIA)
19.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
72 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
New Zealand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Kaden KM36 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––8201,426
Coldresidential3.51.55664,427
Mixedcommercial––1,228753
Mixedresidential3.02.08961,645
Hotcommercial––2,746179
Hotresidential4.02.52,442270
Part-load test points (25 values)
c__t1_min_cap_power_rated
555 W
h__h1_min_cap_power_rated
595 W
h__h2_ext_cap_power_rated
3510 W
c__t1_half_cap_power_rated
1310 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1190 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
2460 W
h__h2_ext_cap_heat_cap_rated
9620 W
h__h1_half_cap_heat_cap_rated
5500 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
450 W
c__t1_min_cap_cooling_cap_rated
2525 W
c__low_temp_full_cap_power_rated
2879.1 W
c__low_temp_half_cap_power_rated
800 W
c__t1_half_cap_cooling_cap_rated
5470 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3330 W
c__low_temp_full_cap_cooling_cap_rated
11847 W
c__low_temp_half_cap_cooling_cap_rated
5500 W

New Zealand E3 registration details

Registration number
AAC7078
GEMS registration id
150099
Status
approved, available (self-reported)
Registration expires
6 October 2027
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 20

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: reece.com.au. How the derived figures are calculated.