c/kWh
Energy rating (cooling)
2
Heating: 0
Annual electricity use
12,454 kWh
955 cooling + 11,499 heating
Estimated running cost
$4,110 / year
$342 / month Β· $41,098 over 10 years
Capacity
14 kW cooling
16 kW heating

84% more electricity than the median of 22 comparable 14 kW reverse cycle multi-split / vrf registrations (6,767 kWh a year) in the cold zone. Uses less than 0% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 11% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

LG ARUN050GSS0 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 12,454$4,110$41,098
Mixed zone 5,894$1,945$19,450
Hot zone 4,584$1,513$15,127

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 14 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RXYMQ5BVM14 kW heating14 kW cooling5,792 kWh/yr2.5$1,911
Daikin RXYMQ5B2VM14 kW heating14 kW cooling5,795 kWh/yr2.5$1,912
Smart User SMV-V180W/N119 kW heating15.5 kW cooling5,831 kWh/yr4$1,924
Samsung Electronics AJ125TXJ5KH/AJ025TNAPKH13.5 kW heating12.5 kW cooling5,843 kWh/yr3$1,928
Ers Tech ERS-AC24KWH19.5 kW heating15.5 kW cooling6,060 kWh/yr4$2,000

Heat pumps similar to the LG ARUN050GSS0

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hisense AVW-48HJFAH116 kW heating14 kW cooling6,528 kWh/yr3.5$2,154
Daikin RXYMQ5BVM14 kW heating14 kW cooling5,792 kWh/yr2.5$1,911
Midea MDV-V140WHN8(At)14 kW heating14 kW cooling6,247 kWh/yr2$2,062
Fujitsu AJT045LCLCH14 kW heating14 kW cooling6,665 kWh/yr2.5$2,199
Carrier 38VS005181HCSG16 kW heating14 kW cooling6,365 kWh/yr3$2,100
Toshiba MCY-MHP0504HS-A16 kW heating14 kW cooling6,365 kWh/yr3$2,100
Daikin RXYMQ5B2VM14 kW heating14 kW cooling5,795 kWh/yr2.5$1,912
Actron Air MMV-140CT16 kW heating14 kW cooling6,767 kWh/yr2.5$2,233

Compare ARUN050GSS0 with another model

LG ARUN050GSS0 specifications

Type
Reverse cycle
Configuration
Multi-split / VRF
Air distribution
Non-ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
14.00 kW
Cooling power input
3.48 kW
Rated heating capacity (7 Β°C)
16.00 kW
Heating power input
3.62 kW
EER, full load (tested)
4.36
COP, full load (tested)
4.64
Rated AEER
3.92
Rated ACOP
4.31
Standby power (PIA)
25.0 W
Compressor
Variable speed, Inverter
Refrigerant
R410A
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
72 dB(A)
Demand response (AS/NZS 4755)
No
Country of manufacture
South Korea

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

LG ARUN050GSS0 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––2,1153,058
Coldresidential2.00.095511,499
Mixedcommercial––2,6081,562
Mixedresidential2.00.01,4404,454
Hotcommercial––5,564292
Hotresidential2.51.54,097487
Part-load test points (16 values)
h__h2_ext_cap_power_rated
1424 W
c__t1_half_cap_power_rated
1742 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1812 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
6000 W
h__h1_half_cap_heat_cap_rated
8000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
7000 W
c__low_temp_have_half_cap_results
No

New Zealand E3 registration details

Registration number
AAC8750
GEMS registration id
168350
Status
approved, available (self-reported)
Registration expires
31 March 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.4:2012
MEPS
2019
Product class
Class 20

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.