c/kWh
Energy rating (cooling)
2.5
Heating: 1.5
Annual electricity use
6,240 kWh
677 cooling + 5,563 heating
Estimated running cost
$2,059 / year
$172 / month Β· $20,592 over 10 years
Capacity
10.5 kW cooling
13 kW heating

31% more electricity than the median of 136 comparable 10 kW reverse cycle ducted split system registrations (4,758 kWh a year) in the cold zone. Uses less than 1% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 29% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

LG UU100WR3 U30 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 6,240$2,059$20,592
Mixed zone 3,078$1,016$10,157
Hot zone 3,267$1,078$10,781

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 10.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Panasonic U-100PZ4R8 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr3$1,199
Panasonic U-100PZ3R5 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr3$1,199
Brivis AONSR13B1/AINHU11B111.3 kW heating10.3 kW cooling3,713 kWh/yr5$1,225
Midea DUCMI105IB/UCMI105OB11 kW heating10.5 kW cooling4,207 kWh/yr4.5$1,388
Midea DUCMI105IHB/UCMI105OB11 kW heating10.5 kW cooling4,207 kWh/yr4.5$1,388

Heat pumps similar to the LG UU100WR3 U30

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Aurora AU-BS36HR-2A-O / AU-LCF36-2A-I11.5 kW heating10.5 kW cooling4,349 kWh/yr4.5$1,435
Actron Air LRC-100CS / LRE-100CS11.5 kW heating10.5 kW cooling4,311 kWh/yr4.5$1,423
Rinnai DONSR11B1/DINLR11B111.5 kW heating10.5 kW cooling4,404 kWh/yr4.5$1,453
Midea DUCMI105IB/UCMI105OB11 kW heating10.5 kW cooling4,207 kWh/yr4.5$1,388
Mdv C-UV-105N8-QC3W / CDV-105A6N8-QC3W11 kW heating10.5 kW cooling4,253 kWh/yr4.5$1,403
Mdv C-UV-105N8-QC3W / CDV-105HN8-QC3W11 kW heating10.5 kW cooling4,244 kWh/yr4.5$1,401
Rinnai DONSR11B1/DINLR11B111.5 kW heating10.5 kW cooling4,403 kWh/yr4.5$1,453
Midea UCMI90OB/DUCMI90IB11 kW heating10.5 kW cooling4,207 kWh/yr4.5$1,388

Compare UU100WR3 U30/UHN100B7 N70 with another model

LG UU100WR3 U30 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
10.50 kW
Cooling power input
2.75 kW
Rated heating capacity (7 Β°C)
13.00 kW
Heating power input
3.10 kW
EER, full load (tested)
3.88
COP, full load (tested)
4.21
Rated AEER
3.75
Rated ACOP
4.13
Standby power (PIA)
15.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China, South Korea

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

LG UU100WR3 U30 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,4911,699
Coldresidential2.51.56775,563
Mixedcommercial––1,853876
Mixedresidential2.52.01,0362,042
Hotcommercial––4,018189
Hotresidential3.02.52,974293
Part-load test points (18 values)
c__t1_half_cap_power_rated
1240 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1400 W
h__h1_have_min_cap_results
No
h__h2_full_cap_power_rated
2680 W
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_half_cap_heat_cap_rated
6600 W
h__h2_full_cap_heat_cap_rated
8350 W
h__h2_is_capable_extended_load
No
c__low_temp_full_cap_power_rated
2513.5 W
c__low_temp_half_cap_power_rated
1133.3600000000001 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
5400 W
c__low_temp_have_half_cap_results
No
c__low_temp_full_cap_cooling_cap_rated
11308.5 W
c__low_temp_half_cap_cooling_cap_rated
5815.8 W

New Zealand E3 registration details

Registration number
AAC8111
GEMS registration id
160136
Status
approved, available (self-reported)
Registration expires
19 March 2029
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.