c/kWh
Energy rating (cooling)
4.5
Heating: 2
Annual electricity use
2,078 kWh
222 cooling + 1,856 heating
Estimated running cost
$686 / year
$57 / month Β· $6,857 over 10 years
Capacity
5 kW cooling
5.3 kW heating

3% less electricity than the median of 236 comparable 5 kW reverse cycle split system registrations (2,154 kWh a year) in the cold zone. Uses less than 69% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 75% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Midea MFEP51VA-W running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,078$686$6,857
Mixed zone 1,008$333$3,326
Hot zone 1,133$374$3,739

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling1,543 kWh/yr4.5$509
Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling1,571 kWh/yr4.5$518
Gree GWH15AGDXD-K6DNA1A/O / GWH15AGDXD-K6DNA1A/I4.7 kW heating4.6 kW cooling1,835 kWh/yr4$606
Gree GWH15QDXE4.7 kW heating4.6 kW cooling1,839 kWh/yr3$607
Midea MFCA50VA-W/MFCA50VA-N5.2 kW heating5.2 kW cooling1,841 kWh/yr4.5$608

Heat pumps similar to the Midea MFEP51VA-W

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hisense HAWG18KR5.3 kW heating5 kW cooling1,993 kWh/yr4$658
Pioneer International HPR-18A25.1 kW heating5 kW cooling1,968 kWh/yr4$649
Kaden KS185.1 kW heating5 kW cooling2,008 kWh/yr3.5$663
Panasonic CU-HZ50DKR / CS-HZ50DKR6 kW heating5 kW cooling1,940 kWh/yr5.5$640
Actron Air WRC-050CS / WRE-050CS5 kW heating5 kW cooling1,936 kWh/yr5$639
Daikin RXM50AVMA / FTXM50AVMA6 kW heating5 kW cooling1,881 kWh/yr5.5$621
Daikin RXM50WVMA / FTXM50WVMA6 kW heating5 kW cooling1,903 kWh/yr5$628
Haier 1U50PFHRA / AS50PFHRA5.3 kW heating5 kW cooling1,973 kWh/yr4$651

Compare MFEP51VA-W/MFEP51VA-N with another model

Midea MFEP51VA-W specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
5.00 kW
Cooling power input
1.25 kW
Rated heating capacity (7 Β°C)
5.30 kW
Heating power input
1.26 kW
EER, full load (tested)
4.05
COP, full load (tested)
4.07
Rated AEER
3.99
Rated ACOP
4.18
Standby power (PIA)
1.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
59.3 dB(A)
Outdoor sound power
68.6 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Midea MFEP51VA-W zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––339575
Coldresidential4.52.02221,856
Mixedcommercial––501289
Mixedresidential4.02.5352656
Hotcommercial––1,28058
Hotresidential4.53.51,04291
Part-load test points (25 values)
c__t1_min_cap_power_rated
441 W
h__h1_min_cap_power_rated
270 W
h__h2_ext_cap_power_rated
1496 W
c__t1_half_cap_power_rated
510 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
480 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1337.8 W
h__h2_ext_cap_heat_cap_rated
4317 W
h__h1_half_cap_heat_cap_rated
2587.8 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
300 W
c__t1_min_cap_cooling_cap_rated
2107 W
c__low_temp_full_cap_power_rated
1142.5 W
c__low_temp_half_cap_power_rated
418 W
c__t1_half_cap_cooling_cap_rated
2480 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
2255 W
c__low_temp_full_cap_cooling_cap_rated
5385 W
c__low_temp_half_cap_cooling_cap_rated
2901 W

New Zealand E3 registration details

Registration number
AAC7968
GEMS registration id
158437
Status
approved, available (self-reported)
Registration expires
13 December 2028
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.