New Zealand Β· costs in NZD

Reverse cycle split system air conditioner
Midea UCMI105OC/DUCMI105IHC Heat Pump
Midea UCMI105OC/DUCMI105IHC is a 10.5 kW reverse cycle ducted split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC8836).
- Energy rating (cooling)
- 4
- Heating: 2
- Annual electricity use
- 4,785 kWh
- 512 cooling + 4,273 heating
- Estimated running cost
- $1,579 / year
- $132 / month Β· $15,791 over 10 years
- Capacity
- 10.5 kW cooling
- 12.5 kW heating
1% more electricity than the median of 136 comparable 10 kW reverse cycle ducted split system registrations (4,758 kWh a year) in the cold zone. Uses less than 43% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 40% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Midea UCMI105OC running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 4,785 | $1,579 | $15,791 |
| Mixed zone | 2,355 | $777 | $7,772 |
| Hot zone | 2,520 | $832 | $8,316 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 10.5 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-100PZ4R8 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr | 3 | $1,199 | |
| Panasonic U-100PZ3R5 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr | 3 | $1,199 | |
| Brivis AONSR13B1/AINHU11B111.3 kW heating10.3 kW cooling3,713 kWh/yr | 5 | $1,225 | |
| Midea UCMI90OB/DUCMI90IB11 kW heating10.5 kW cooling4,207 kWh/yr | 4.5 | $1,388 | |
| Midea DUCMI105IB/UCMI105OB11 kW heating10.5 kW cooling4,207 kWh/yr | 4.5 | $1,388 |
Heat pumps similar to the Midea UCMI105OC
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Kaden KDI36 / KDI3611.5 kW heating10.5 kW cooling4,427 kWh/yr | 4.5 | $1,461 | |
| Aurora AU-BS36HR-2A-O / AU-LCF36-2A-I11.5 kW heating10.5 kW cooling4,349 kWh/yr | 4.5 | $1,435 | |
| Actron Air LRC-100CS / LRE-100CS11.5 kW heating10.5 kW cooling4,311 kWh/yr | 4.5 | $1,423 | |
| Rinnai DONSR11B1/DINLR11B111.5 kW heating10.5 kW cooling4,404 kWh/yr | 4.5 | $1,453 | |
| Mdv C-UV-105N8-QC3W / CDV-105A6N8-QC3W11 kW heating10.5 kW cooling4,253 kWh/yr | 4.5 | $1,403 | |
| Mdv C-UV-105N8-QC3W / CDV-105HN8-QC3W11 kW heating10.5 kW cooling4,244 kWh/yr | 4.5 | $1,401 | |
| Rinnai DONSR11B1/DINLR11B111.5 kW heating10.5 kW cooling4,403 kWh/yr | 4.5 | $1,453 | |
| Kaden KDI3611.5 kW heating10.5 kW cooling4,565 kWh/yr | 3 | $1,506 |
Compare UCMI105OC/DUCMI105IHC with another model
Midea UCMI105OC specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 10.50 kW
- Cooling power input
- 3.15 kW
- Rated heating capacity (7 Β°C)
- 12.50 kW
- Heating power input
- 2.98 kW
- EER, full load (tested)
- 3.28
- COP, full load (tested)
- 4.29
- Rated AEER
- 3.30
- Rated ACOP
- 4.14
- Standby power (PIA)
- 10.8 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- 68.1 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Midea UCMI105OC zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 249 | 1,319 |
| Coldresidential | residential | 4.0 | 2.0 | 512 | 4,273 |
| Mixedcommercial | commercial | β | β | 866 | 669 |
| Mixedresidential | residential | 3.5 | 3.0 | 818 | 1,537 |
| Hotcommercial | commercial | β | β | 2,348 | 147 |
| Hotresidential | residential | 4.0 | 3.5 | 2,292 | 228 |
Part-load test points (23 values)
- c__t1_min_cap_power_rated
- 625 W
- h__h1_min_cap_power_rated
- 503 W
- h__h2_ext_cap_power_rated
- 3160 W
- c__t1_half_cap_power_rated
- 1390 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 1186 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 2650 W
- h__h2_ext_cap_heat_cap_rated
- 10150 W
- h__h1_half_cap_heat_cap_rated
- 6300 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 368 W
- c__t1_min_cap_cooling_cap_rated
- 2600 W
- c__low_temp_half_cap_power_rated
- 833 W
- c__t1_half_cap_cooling_cap_rated
- 5200 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 2620 W
- c__low_temp_half_cap_cooling_cap_rated
- 5520 W
New Zealand E3 registration details
- Registration number
- AAC8836
- GEMS registration id
- 169117
- Status
- approved, available (self-reported)
- Registration expires
- 8 May 2030
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 11
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.