c/kWh
Energy rating (cooling)
2
Heating: 2
Annual electricity use
6,812 kWh
935 cooling + 5,877 heating
Estimated running cost
$2,248 / year
$187 / month Β· $22,480 over 10 years
Capacity
14 kW cooling
16 kW heating

1% more electricity than the median of 124 comparable 14 kW reverse cycle ducted split system registrations (6,763 kWh a year) in the cold zone. Uses less than 44% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 25% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Mitsubishi Electric PUZ-ZM140YKA-A running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 6,812$2,248$22,480
Mixed zone 3,666$1,210$12,098
Hot zone 4,444$1,467$14,665

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 14 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RZA160CV1 / FDYAN160AV118 kW heating15.5 kW cooling4,493 kWh/yr2$1,483
Panasonic U-125PZ4R8 / S-125PE4*12.5 kW heating12.5 kW cooling4,742 kWh/yr3$1,565
Panasonic U-125PZ4R8 / S-125PE4RN12.5 kW heating12.5 kW cooling4,742 kWh/yr3$1,565
Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling4,776 kWh/yr4$1,576
Rinnai DONSR13B1/DINLR13B113 kW heating12.5 kW cooling4,830 kWh/yr4$1,594

Heat pumps similar to the Mitsubishi Electric PUZ-ZM140YKA-A

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Mdv C-UV-140N8-QC3W / CDV-140HFN8-QC3W14.5 kW heating14 kW cooling5,664 kWh/yr4$1,869
Midea UCMI140OB/DUCMI140IHB14.5 kW heating14 kW cooling5,658 kWh/yr4$1,867
Actron Air URC-140CS / LRE-140CS14.3 kW heating14 kW cooling5,513 kWh/yr4$1,819
Rinnai DONSR15B1/DINLR15B114.5 kW heating14 kW cooling5,618 kWh/yr4$1,854
Kaden KDI48 / KDI4814 kW heating14 kW cooling5,394 kWh/yr4$1,780
Mdv C-UV-140N8-QC3W / CDV-140A6N8-QC3W14.5 kW heating14 kW cooling5,607 kWh/yr3.5$1,850
Actron Air URC-140DS / LRE-140DS15.5 kW heating14 kW cooling5,768 kWh/yr4$1,903
Midea DUCMI140IHB/UCMI140OB14.5 kW heating14 kW cooling5,596 kWh/yr4$1,847

Compare PUZ-ZM140YKA-A/PEAD-M140JAAD with another model

Mitsubishi Electric PUZ-ZM140YKA-A specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
14.00 kW
Cooling power input
4.37 kW
Rated heating capacity (7 Β°C)
16.00 kW
Heating power input
4.18 kW
EER, full load (tested)
3.76
COP, full load (tested)
4.06
Rated AEER
3.12
Rated ACOP
3.73
Standby power (PIA)
33.6 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
Dimensions (WΓ—HΓ—D)
1600 Γ— 250 Γ— 732 mm
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Mitsubishi Electric PUZ-ZM140YKA-A zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,9301,902
Coldresidential2.02.09355,877
Mixedcommercial––2,4291,009
Mixedresidential2.02.51,4512,215
Hotcommercial––5,373253
Hotresidential2.53.04,064380
Part-load test points (16 values)
h__h2_ext_cap_power_rated
5710 W
c__t1_half_cap_power_rated
1460 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1620 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
14900 W
h__h1_half_cap_heat_cap_rated
8000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
7000 W
c__low_temp_have_half_cap_results
No

Other model numbers on registration AAC7877

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC7877
GEMS registration id
157868
Status
approved, available (self-reported)
Registration expires
13 November 2028
Registered for sale in
Australia, New Zealand
Family
PUZ-ZM140YKA2-A/PEAD-M140JAA(D)2 Series
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: MitsubishiElectric.com.au. How the derived figures are calculated.