c/kWh
Energy rating (cooling)
4
Heating: 2
Annual electricity use
1,032 kWh
117 cooling + 915 heating
Estimated running cost
$341 / year
$28 / month Β· $3,406 over 10 years
Capacity
2.5 kW cooling
2.8 kW heating

4% less electricity than the median of 177 comparable 2.5 kW reverse cycle split system registrations (1,073 kWh a year) in the cold zone. Uses less than 55% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 88% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Panasonic CU-QZ25BKR running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,032$341$3,406
Mixed zone 528$174$1,742
Hot zone 593$196$1,957

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 2.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Hitachi RAC-VJ25NHAE/RAI-VJ25RHAE3.5 kW heating2.5 kW cooling653 kWh/yr4$215
Daikin RXM20AVMA / FTXM20AVMA2.7 kW heating2.2 kW cooling725 kWh/yr6$239
Midea MFEP26VA-W/MFEP26VA-N2.7 kW heating2.6 kW cooling776 kWh/yr6.5$256
Actron Air WRC-026DS / WRE-026DS2.7 kW heating2.6 kW cooling790 kWh/yr7$261
Midea MFEP26VB-W/MFEP26VB-N2.7 kW heating2.6 kW cooling790 kWh/yr7$261

Heat pumps similar to the Panasonic CU-QZ25BKR

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Rinnai HSNRTX252.8 kW heating2.5 kW cooling897 kWh/yr5$296
Midea MFAG26VB-W/MFAG26VB-N2.8 kW heating2.5 kW cooling897 kWh/yr5$296
Pioneer International HPR-09A22.6 kW heating2.5 kW cooling845 kWh/yr4$279
Carrier 42QHG026N8PB/38QUH026N8PB2.8 kW heating2.5 kW cooling897 kWh/yr5$296
Carrier 38QRF026N8/42QRF026N82.8 kW heating2.5 kW cooling897 kWh/yr5$296
Rinnai HONRTX25/HINRTX252.8 kW heating2.5 kW cooling897 kWh/yr5$296
Daikin RXM25AVMA / FTXM25AVMA3.2 kW heating2.5 kW cooling888 kWh/yr6$293
Kaden KSI-2.52.8 kW heating2.5 kW cooling897 kWh/yr5$296

Compare CU-QZ25BKR/CS-QZ25BKR with another model

Panasonic CU-QZ25BKR specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
2.50 kW
Cooling power input
0.58 kW
Rated heating capacity (7 Β°C)
2.79 kW
Heating power input
0.61 kW
EER, full load (tested)
4.61
COP, full load (tested)
4.91
Rated AEER
4.25
Rated ACOP
4.56
Standby power (PIA)
0.8 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
56.7 dB(A)
Outdoor sound power
59.1 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic CU-QZ25BKR zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––236300
Coldresidential4.02.0117915
Mixedcommercial––308159
Mixedresidential4.02.5183345
Hotcommercial––70833
Hotresidential4.53.054152
Part-load test points (23 values)
c__t1_min_cap_power_rated
155 W
h__h1_min_cap_power_rated
220 W
h__h2_ext_cap_power_rated
1190 W
c__t1_half_cap_power_rated
227 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
280 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1056 W
h__h2_ext_cap_heat_cap_rated
3005 W
h__h1_half_cap_heat_cap_rated
1420 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
135 W
c__t1_min_cap_cooling_cap_rated
829 W
c__low_temp_half_cap_power_rated
190 W
c__t1_half_cap_cooling_cap_rated
1219 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
939 W
c__low_temp_half_cap_cooling_cap_rated
1312 W

New Zealand E3 registration details

Registration number
AAC8647
GEMS registration id
167956
Status
approved, available (self-reported)
Registration expires
11 March 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. Manufacturer: panasonic.com/au. How the derived figures are calculated.