c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
2,460 kWh
250 cooling + 2,210 heating
Estimated running cost
$812 / year
$68 / month Β· $8,118 over 10 years
Capacity
5 kW cooling
6 kW heating

14% more electricity than the median of 236 comparable 5 kW reverse cycle split system registrations (2,154 kWh a year) in the cold zone. Uses less than 9% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 69% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Panasonic CU-RZ50DKR running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,460$812$8,118
Mixed zone 1,199$396$3,957
Hot zone 1,298$428$4,283

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling1,543 kWh/yr4.5$509
Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling1,571 kWh/yr4.5$518
Gree GWH15AGDXD-K6DNA1A/O / GWH15AGDXD-K6DNA1A/I4.7 kW heating4.6 kW cooling1,835 kWh/yr4$606
Gree GWH15QDXE4.7 kW heating4.6 kW cooling1,839 kWh/yr3$607
Midea MFCA50VA-W/MFCA50VA-N5.2 kW heating5.2 kW cooling1,841 kWh/yr4.5$608

Heat pumps similar to the Panasonic CU-RZ50DKR

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Daikin RXM50WVMA / FTXM50WVMA6 kW heating5 kW cooling1,903 kWh/yr5$628
Daikin RXM50AVMA / FTXM50AVMA6 kW heating5 kW cooling1,881 kWh/yr5.5$621
Haier 1U50PFHRA / AS50PFHRA5.3 kW heating5 kW cooling1,973 kWh/yr4$651
Hisense HAWG18KR5.3 kW heating5 kW cooling1,993 kWh/yr4$658
Pioneer International HPR-18A25.1 kW heating5 kW cooling1,968 kWh/yr4$649
LG LS18S0U DX6ALAP/LS18S0N DX6ALAP5.1 kW heating5 kW cooling2,018 kWh/yr3$666
Kaden KS185.1 kW heating5 kW cooling2,008 kWh/yr3.5$663
Actron Air WRC-050CS / WRE-050CS5 kW heating5 kW cooling1,936 kWh/yr5$639

Compare CU-RZ50DKR / CS-RZ50DKRW with another model

Panasonic CU-RZ50DKR specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
5.00 kW
Cooling power input
1.51 kW
Rated heating capacity (7 Β°C)
6.00 kW
Heating power input
1.72 kW
EER, full load (tested)
3.27
COP, full load (tested)
3.38
Rated AEER
3.29
Rated ACOP
3.47
Standby power (PIA)
2.5 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
60 dB(A)
Outdoor sound power
63 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic CU-RZ50DKR zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––425675
Coldresidential3.52.02502,210
Mixedcommercial––591342
Mixedresidential3.52.5401798
Hotcommercial––1,49369
Hotresidential3.53.01,188110
Part-load test points (23 values)
c__t1_min_cap_power_rated
210 W
h__h1_min_cap_power_rated
230 W
h__h2_ext_cap_power_rated
2200 W
c__t1_half_cap_power_rated
510 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
590 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1100 W
h__h2_ext_cap_heat_cap_rated
5500 W
h__h1_half_cap_heat_cap_rated
3000 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
165 W
c__t1_min_cap_cooling_cap_rated
1100 W
c__low_temp_half_cap_power_rated
415 W
c__t1_half_cap_cooling_cap_rated
2500 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
1310 W
c__low_temp_half_cap_cooling_cap_rated
2720 W

Other model numbers on registration AAC10223

Registered together and sharing the same test results. Usually variants of the same unit.

New Zealand E3 registration details

Registration number
AAC10223
GEMS registration id
178909
Status
approved, available (self-reported)
Registration expires
4 June 2031
Registered for sale in
Australia, New Zealand
Family
CU-*Z50DKR / CS-*Z50DKRW
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: papamy.panasonic.com.my. How the derived figures are calculated.