c/kWh
Energy rating (cooling)
0
Heating: 2
Annual electricity use
5,659 kWh
800 cooling + 4,859 heating
Estimated running cost
$1,867 / year
$156 / month Β· $18,675 over 10 years
Capacity
13.4 kW cooling
13.4 kW heating

16% less electricity than the median of 124 comparable 14 kW reverse cycle ducted split system registrations (6,763 kWh a year) in the cold zone. Uses less than 90% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 34% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Panasonic U-140PZ3R8 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 5,659$1,867$18,675
Mixed zone 3,050$1,007$10,065
Hot zone 3,929$1,297$12,966

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 13.4 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Brivis AONSR13B1/AINHU13B113.8 kW heating12 kW cooling4,365 kWh/yr4.5$1,440
Panasonic U-125PZ3R8 / S-1014PF3E12.1 kW heating12.1 kW cooling4,458 kWh/yr3$1,471
Panasonic U-125PZ4R8 / S-125PE4*12.5 kW heating12.5 kW cooling4,742 kWh/yr3$1,565
Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling4,776 kWh/yr4$1,576
Carrier 38QSM125D8S/42QSM125D8S13 kW heating12.3 kW cooling4,798 kWh/yr3.5$1,583

Heat pumps similar to the Panasonic U-140PZ3R8

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Bonaire CRC6960014/CRC696011416 kW heating13.5 kW cooling7,954 kWh/yr2.5$2,625
Brivis AONSR15B1/AINHU15B115.7 kW heating13.6 kW cooling5,308 kWh/yr5$1,752
Braemar KCHV160D1B/KGHV200A1S17 kW heating13.2 kW cooling7,336 kWh/yr3$2,421
Braemar KCHV160D1B/KGHV200A1T17 kW heating13.2 kW cooling7,336 kWh/yr3$2,421
Carrier 38QSH140D8S-1/42QSH140D8S-114.3 kW heating13.6 kW cooling5,575 kWh/yr4$1,840
Actron Air CRV13AS / EVV13AS13.4 kW heating13.2 kW cooling10,211 kWh/yr2.5$3,370
Actron Air CRV13AS / EAA13AS & EFV13AS13.4 kW heating13.2 kW cooling10,211 kWh/yr2.5$3,370
Carrier 38QSM140D8S/42QSM140D8S14.5 kW heating13.6 kW cooling5,575 kWh/yr3.5$1,840

Compare U-140PZ3R8 / S-1014PF3E with another model

Panasonic U-140PZ3R8 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
13.40 kW
Cooling power input
4.24 kW
Rated heating capacity (7 Β°C)
13.40 kW
Heating power input
3.56 kW
EER, full load (tested)
3.23
COP, full load (tested)
3.68
Rated AEER
3.11
Rated ACOP
3.70
Standby power (PIA)
19.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China, Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-140PZ3R8 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1221,526
Coldresidential0.02.08004,859
Mixedcommercial––1,864771
Mixedresidential0.02.51,2571,793
Hotcommercial––4,418179
Hotresidential10.03.03,654275
Part-load test points (23 values)
c__t1_min_cap_power_rated
650 W
h__h1_min_cap_power_rated
650 W
h__h2_ext_cap_power_rated
4400 W
c__t1_half_cap_power_rated
1380 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1400 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3400 W
h__h2_ext_cap_heat_cap_rated
12000 W
h__h1_half_cap_heat_cap_rated
6700 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
540 W
c__t1_min_cap_cooling_cap_rated
3300 W
c__low_temp_half_cap_power_rated
1200 W
c__t1_half_cap_cooling_cap_rated
6700 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3600 W
c__low_temp_half_cap_cooling_cap_rated
7000 W

New Zealand E3 registration details

Registration number
AAC9034
GEMS registration id
169364
Status
approved, available (self-reported)
Registration expires
27 September 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: papamy.panasonic.com.my. How the derived figures are calculated.