c/kWh
Energy rating (cooling)
3
Heating: 2
Annual electricity use
6,332 kWh
764 cooling + 5,568 heating
Estimated running cost
$2,090 / year
$174 / month Β· $20,896 over 10 years
Capacity
13.4 kW cooling
15.5 kW heating

6% less electricity than the median of 124 comparable 14 kW reverse cycle ducted split system registrations (6,763 kWh a year) in the cold zone. Uses less than 80% of them.

Across all 3,566 air conditioner registrations sold in Australia, it uses less than 29% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Panasonic U-140PZH3R8 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 6,332$2,090$20,896
Mixed zone 3,270$1,079$10,791
Hot zone 3,783$1,248$12,484

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 13.4 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Brivis AONSR13B1/AINHU13B113.8 kW heating12 kW cooling4,365 kWh/yr4.5$1,440
Panasonic U-125PZ3R8 / S-1014PF3E12.1 kW heating12.1 kW cooling4,458 kWh/yr3$1,471
Panasonic U-125PZ4R8 / S-125PE4R12.5 kW heating12.5 kW cooling4,742 kWh/yr3$1,565
Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling4,776 kWh/yr4$1,576
Carrier 38QSM125D8S/42QSM125D8S13 kW heating12.3 kW cooling4,798 kWh/yr3.5$1,583

Heat pumps similar to the Panasonic U-140PZH3R8

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Bonaire CRC6960014/CRC696011416 kW heating13.5 kW cooling7,954 kWh/yr2.5$2,625
Braemar KCHV160D1B/KGHV200A1S17 kW heating13.2 kW cooling7,336 kWh/yr3$2,421
Braemar KCHV160D1B/KGHV200A1T17 kW heating13.2 kW cooling7,336 kWh/yr3$2,421
Brivis AONSR15B1/AINHU15B115.7 kW heating13.6 kW cooling5,308 kWh/yr5$1,752
Actron Air CRV13AS / EVV13AS13.4 kW heating13.2 kW cooling10,211 kWh/yr2.5$3,370
Actron Air CRV13AS / EAA13AS & EFV13AS13.4 kW heating13.2 kW cooling10,211 kWh/yr2.5$3,370
Carrier 38QSH140D8S-1/42QSH140D8S-114.3 kW heating13.6 kW cooling5,575 kWh/yr4$1,840
Carrier 38QSM140D8S/42QSM140D8S14.5 kW heating13.6 kW cooling5,575 kWh/yr3.5$1,840

Compare U-140PZH3R8/S-1014PF3E with another model

Panasonic U-140PZH3R8 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
13.40 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
15.50 kW
Heating power input
–
EER, full load (tested)
3.54
COP, full load (tested)
3.62
Rated AEER
3.34
Rated ACOP
3.40
Standby power (PIA)
15.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-140PZH3R8 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,5371,702
Coldresidential3.02.07645,568
Mixedcommercial––1,977878
Mixedresidential3.02.51,2032,067
Hotcommercial––4,551191
Hotresidential3.03.03,484299
Part-load test points (22 values)
h__h1_min_cap_power_rated
660 W
h__h2_ext_cap_power_rated
5600 W
c__t1_half_cap_power_rated
1400 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1550 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3400 W
h__h2_ext_cap_heat_cap_rated
15000 W
h__h1_half_cap_heat_cap_rated
7750 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
550 W
c__low_temp_half_cap_power_rated
1190 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
6700 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3600 W
c__low_temp_half_cap_cooling_cap_rated
7200 W

New Zealand E3 registration details

Registration number
AAC9635
GEMS registration id
–
Status
approved
Registration expires
8 December 2030
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS