c/kWh
Energy rating (cooling)
2
Heating: 2.5
Annual electricity use
1,232 kWh
167 cooling + 1,065 heating
Estimated running cost
$407 / year
$34 / month Β· $4,066 over 10 years
Capacity
2.5 kW cooling
3.2 kW heating

15% more electricity than the median of 175 comparable 2.5 kW reverse cycle split system registrations (1,073 kWh a year) in the cold zone. Uses less than 15% of them.

Across all 3,566 air conditioner registrations sold in Australia, it uses less than 85% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Panasonic U-25PZ3R5 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,232$407$4,066
Mixed zone 664$219$2,191
Hot zone 718$237$2,369

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 2.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Fujitsu AOTH09KNCA / ASTH09KNCA3.2 kW heating2.5 kW cooling0 kWh/yr–$0
Hitachi RAC-VJ25NHAE/RAI-VJ25RHAE3.5 kW heating2.5 kW cooling653 kWh/yr4$215
Daikin RXM20AVMA / FTXM20AVMA2.7 kW heating2.2 kW cooling725 kWh/yr6$239
Midea MFEP26VA-W/MFEP26VA-N2.7 kW heating2.6 kW cooling776 kWh/yr6.5$256
Actron Air WRC-026DS / WRE-026DS2.7 kW heating2.6 kW cooling790 kWh/yr7$261

Heat pumps similar to the Panasonic U-25PZ3R5

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hitachi RAC-VJ25NHAE/RAI-VJ25RHAE3.5 kW heating2.5 kW cooling653 kWh/yr4$215
Daikin RXM25AVMA / FTXM25AVMA3.2 kW heating2.5 kW cooling888 kWh/yr6$293
Rinnai HSNRTX252.8 kW heating2.5 kW cooling897 kWh/yr5$296
Rinnai HONRTX25/HINRTX252.8 kW heating2.5 kW cooling897 kWh/yr5$296
Fujitsu AOTH09KNCA / ASTH09KNCA3.2 kW heating2.5 kW cooling0 kWh/yr–$0
Carrier 38QAF026N8/42QAF026N82.8 kW heating2.5 kW cooling897 kWh/yr5$296
Midea MFAG26VB-W/MFAG26VB-N2.8 kW heating2.5 kW cooling897 kWh/yr5$296
Carrier 38QRF026N8/42QRF026N82.8 kW heating2.5 kW cooling897 kWh/yr5$296

Compare U-25PZ3R5/S-25PY3E with another model

Panasonic U-25PZ3R5 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Cassette
Rated cooling capacity (35 Β°C)
2.50 kW
Cooling power input
–
Rated heating capacity (7 Β°C)
3.20 kW
Heating power input
–
EER, full load (tested)
4.53
COP, full load (tested)
4.64
Rated AEER
4.19
Rated ACOP
4.23
Standby power (PIA)
11.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Malaysia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Panasonic U-25PZ3R5 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––349355
Coldresidential2.02.51671,065
Mixedcommercial––433195
Mixedresidential2.03.0250414
Hotcommercial––85156
Hotresidential3.03.063781
Part-load test points (20 values)
h__h1_min_cap_power_rated
250 W
c__t1_half_cap_power_rated
270 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
290 W
h__h1_have_min_cap_results
Yes
h__h2_full_cap_power_rated
1160 W
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1300 W
h__h1_half_cap_heat_cap_rated
1600 W
h__h2_full_cap_heat_cap_rated
3330 W
h__h2_is_capable_extended_load
No
c__low_temp_min_cap_power_rated
270 W
c__low_temp_half_cap_power_rated
220 W
c__low_temp_have_min_cap_results
Yes
c__t1_half_cap_cooling_cap_rated
1370 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
1370 W
c__low_temp_half_cap_cooling_cap_rated
1450 W

New Zealand E3 registration details

Registration number
AAC10455
GEMS registration id
–
Status
approved
Registration expires
10 November 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
8