c/kWh
Energy rating (cooling)
4
Heating: 3
Annual electricity use
845 kWh
111 cooling + 734 heating
Estimated running cost
$279 / year
$23 / month Β· $2,789 over 10 years
Capacity
2.5 kW cooling
2.6 kW heating

21% less electricity than the median of 178 comparable 2.5 kW reverse cycle split system registrations (1,074 kWh a year) in the cold zone. Uses less than 92% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 91% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Pioneer International HPR-09A2 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 845$279$2,789
Mixed zone 418$138$1,379
Hot zone 992$327$3,274

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 2.5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Hitachi RAC-VJ25NHAE/RAI-VJ25RHAE3.5 kW heating2.5 kW cooling653 kWh/yr4$215
Daikin RXM20AVMA / FTXM20AVMA2.7 kW heating2.2 kW cooling725 kWh/yr6$239
Midea MFEP26VA-W/MFEP26VA-N2.7 kW heating2.6 kW cooling776 kWh/yr6.5$256
Midea MFEP26VB-W/MFEP26VB-N2.7 kW heating2.6 kW cooling790 kWh/yr7$261
Actron Air WRC-026DS / WRE-026DS2.7 kW heating2.6 kW cooling790 kWh/yr7$261

Heat pumps similar to the Pioneer International HPR-09A2

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Carrier 38QRF026N8/42QRF026N82.8 kW heating2.5 kW cooling897 kWh/yr5$296
Kaden KSI-2.52.8 kW heating2.5 kW cooling897 kWh/yr5$296
Rinnai HSNRTX252.8 kW heating2.5 kW cooling897 kWh/yr5$296
Carrier 38QAF026N8/42QAF026N82.8 kW heating2.5 kW cooling897 kWh/yr5$296
Midea MFAG26VB-W/MFAG26VB-N2.8 kW heating2.5 kW cooling897 kWh/yr5$296
Daikin RXM25AVMA / FTXM25AVMA3.2 kW heating2.5 kW cooling888 kWh/yr6$293
Rinnai HONRTX25/HINRTX252.8 kW heating2.5 kW cooling897 kWh/yr5$296
Comfee CASG-XG26B/CASN-XG26B2.8 kW heating2.5 kW cooling897 kWh/yr5$296

Compare HPR-09A2 with another model

Pioneer International HPR-09A2 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
2.50 kW
Cooling power input
0.63 kW
Rated heating capacity (7 Β°C)
2.60 kW
Heating power input
0.55 kW
EER, full load (tested)
3.98
COP, full load (tested)
4.81
Rated AEER
3.93
Rated ACOP
4.67
Standby power (PIA)
2.0 W
Compressor
Variable speed, Inverter
Refrigerant
M50
Power supply
Single phase
Indoor sound power
39 dB(A)
Outdoor sound power
52 dB(A)
Demand response (AS/NZS 4755)
No
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Pioneer International HPR-09A2 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––52233
Coldresidential4.03.0111734
Mixedcommercial––-90128
Mixedresidential4.03.5172246
Hotcommercial––58927
Hotresidential4.54.0437555
Part-load test points (27 values)
c__t1_min_cap_power_rated
172 W
h__h1_min_cap_power_rated
146 W
c__t1_half_cap_power_rated
270 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
220 W
h__h1_have_min_cap_results
Yes
h__h2_full_cap_power_rated
1416 W
h__h2_half_cap_power_rated
410 W
h__h3_full_cap_power_rated
1346 W
h__h3_half_cap_power_rated
480 W
h__h2_have_half_cap_results
Yes
h__h3_have_full_cap_results
Yes
h__h3_have_half_cap_results
Yes
h__h1_min_cap_heat_cap_rated
902 W
h__h1_half_cap_heat_cap_rated
1292 W
h__h2_full_cap_heat_cap_rated
3571 W
h__h2_half_cap_heat_cap_rated
1752 W
h__h3_full_cap_heat_cap_rated
3180 W
h__h3_half_cap_heat_cap_rated
1602 W
h__h2_is_capable_extended_load
No
c__low_temp_min_cap_power_rated
84 W
c__t1_min_cap_cooling_cap_rated
575 W
c__low_temp_half_cap_power_rated
210 W
c__t1_half_cap_cooling_cap_rated
1281 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
584 W
c__low_temp_half_cap_cooling_cap_rated
1310 W

New Zealand E3 registration details

Registration number
AAC10453
GEMS registration id
182210
Status
approved, available (self-reported)
Registration expires
25 October 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. How the derived figures are calculated.