c/kWh
Energy rating (cooling)
4
Heating: 2
Annual electricity use
1,968 kWh
234 cooling + 1,734 heating
Estimated running cost
$649 / year
$54 / month Β· $6,494 over 10 years
Capacity
5 kW cooling
5.1 kW heating

9% less electricity than the median of 236 comparable 5 kW reverse cycle split system registrations (2,154 kWh a year) in the cold zone. Uses less than 88% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 77% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Pioneer International HPR-18A2 running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,968$649$6,494
Mixed zone 1,026$339$3,386
Hot zone 1,219$402$4,023

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling1,543 kWh/yr4.5$509
Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling1,571 kWh/yr4.5$518
Gree GWH15AGDXD-K6DNA1A/O / GWH15AGDXD-K6DNA1A/I4.7 kW heating4.6 kW cooling1,835 kWh/yr4$606
Gree GWH15QDXE-K6DNA1A/O / GWH15QDXE-K6DNA1A/I4.7 kW heating4.6 kW cooling1,839 kWh/yr3$607
Midea MFCA50VA-W/MFCA50VA-N5.2 kW heating5.2 kW cooling1,841 kWh/yr4.5$608

Heat pumps similar to the Pioneer International HPR-18A2

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Actron Air WRC-050CS / WRE-050CS5 kW heating5 kW cooling1,936 kWh/yr5$639
LG LS18S0U DX6ALAP/LS18S0N DX6ALAP5.1 kW heating5 kW cooling2,018 kWh/yr3$666
Daikin RXM50AVMA / FTXM50AVMA6 kW heating5 kW cooling1,881 kWh/yr5.5$621
Daikin RXM50WVMA / FTXM50WVMA6 kW heating5 kW cooling1,903 kWh/yr5$628
Haier 1U50PFHRA / AS50PFHRA5.3 kW heating5 kW cooling1,973 kWh/yr4$651
Hisense HAWG18KR5.3 kW heating5 kW cooling1,993 kWh/yr4$658
Kaden KS185.1 kW heating5 kW cooling2,008 kWh/yr3.5$663
Panasonic CU-HZ50DKR / CS-HZ50DKR6 kW heating5 kW cooling1,940 kWh/yr5.5$640

Compare HPR-18A2 with another model

Pioneer International HPR-18A2 specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
5.00 kW
Cooling power input
1.54 kW
Rated heating capacity (7 Β°C)
5.10 kW
Heating power input
1.35 kW
EER, full load (tested)
3.37
COP, full load (tested)
3.90
Rated AEER
3.23
Rated ACOP
3.76
Standby power (PIA)
2.0 W
Compressor
Variable speed, Inverter
Refrigerant
M50
Power supply
Single phase
Indoor sound power
44 dB(A)
Outdoor sound power
55 dB(A)
Demand response (AS/NZS 4755)
No
Country of manufacture
Australia, China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Pioneer International HPR-18A2 zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––371515
Coldresidential4.02.02341,734
Mixedcommercial––-42259
Mixedresidential4.02.5371655
Hotcommercial––49951
Hotresidential4.03.51,13485
Part-load test points (27 values)
c__t1_min_cap_power_rated
195 W
h__h1_min_cap_power_rated
210 W
c__t1_half_cap_power_rated
512 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
475 W
h__h1_have_min_cap_results
Yes
h__h2_full_cap_power_rated
1970 W
h__h2_half_cap_power_rated
738 W
h__h3_full_cap_power_rated
1973 W
h__h3_half_cap_power_rated
853 W
h__h2_have_half_cap_results
Yes
h__h3_have_full_cap_results
Yes
h__h3_have_half_cap_results
Yes
h__h1_min_cap_heat_cap_rated
1270 W
h__h1_half_cap_heat_cap_rated
2508 W
h__h2_full_cap_heat_cap_rated
5167 W
h__h2_half_cap_heat_cap_rated
2575 W
h__h3_full_cap_heat_cap_rated
5012 W
h__h3_half_cap_heat_cap_rated
2466 W
h__h2_is_capable_extended_load
No
c__low_temp_min_cap_power_rated
101 W
c__t1_min_cap_cooling_cap_rated
596 W
c__low_temp_half_cap_power_rated
406 W
c__t1_half_cap_cooling_cap_rated
2459 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
759 W
c__low_temp_half_cap_cooling_cap_rated
2523 W

New Zealand E3 registration details

Registration number
AAC10452
GEMS registration id
182213
Status
approved, available (self-reported)
Registration expires
17 October 2031
Registered for sale in
Australia, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. How the derived figures are calculated.