New Zealand Β· costs in NZD

Reverse cycle split system air conditioner, floor mounted
Rinnai HONRP50B / FINRP50MBNZ Heat Pump
Rinnai HONRP50B / FINRP50MBNZ is a 4.7 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration ZAC0800).
- Energy rating (cooling)
- 4
- Heating: 2
- Annual electricity use
- 2,017 kWh
- 222 cooling + 1,795 heating
- Estimated running cost
- $666 / year
- $55 / month Β· $6,656 over 10 years
- Capacity
- 4.7 kW cooling
- 5.2 kW heating
6% less electricity than the median of 236 comparable 5 kW reverse cycle split system registrations (2,154 kWh a year) in the cold zone. Uses less than 81% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 77% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Rinnai HONRP50B running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 2,017 | $666 | $6,656 |
| Mixed zone | 1,018 | $336 | $3,359 |
| Hot zone | 1,156 | $381 | $3,815 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 4.7 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling1,543 kWh/yr | 4.5 | $509 | |
| Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling1,571 kWh/yr | 4.5 | $518 | |
| Fujitsu AOTH14KNCA/ASTH14KNCA4.7 kW heating4.2 kW cooling1,822 kWh/yr | 4 | $601 | |
| Gree GWH15AGDXD-K6DNA1A/O / GWH15AGDXD-K6DNA1A/I4.7 kW heating4.6 kW cooling1,835 kWh/yr | 4 | $606 | |
| Gree GWH15QDXE-K6DNA1A/O / GWH15QDXE-K6DNA1A/I4.7 kW heating4.6 kW cooling1,839 kWh/yr | 3 | $607 |
Heat pumps similar to the Rinnai HONRP50B
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Toshiba RAS-16E2AVRG-A / RAS-B16E2KVRG-A5.5 kW heating4.6 kW cooling2,922 kWh/yr | 3 | $964 | |
| LG AS18S1U / AS18S1N5.2 kW heating4.8 kW cooling2,188 kWh/yr | 3.5 | $722 | |
| Gree GWH15AGDXD-K6DNA1A/O / GWH15AGDXD-K6DNA1A/I4.7 kW heating4.6 kW cooling1,835 kWh/yr | 4 | $606 | |
| Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling1,543 kWh/yr | 4.5 | $509 | |
| LG WS18TWU / WS18TWN5.9 kW heating4.8 kW cooling2,712 kWh/yr | 3.5 | $895 | |
| Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling1,571 kWh/yr | 4.5 | $518 | |
| Gree GWH15QDXE-K6DNA1A/O / GWH15QDXE-K6DNA1A/I4.7 kW heating4.6 kW cooling1,839 kWh/yr | 3 | $607 |
Other Rinnai models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Rinnai FSNRP50B5.5 kW heating4.9 kW cooling2,122 kWh/yr | 4.5 | $700 |
Compare HONRP50B / FINRP50MBNZ with another model
Rinnai HONRP50B specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Floor mounted
- Rated cooling capacity (35 Β°C)
- 4.70 kW
- Cooling power input
- 1.44 kW
- Rated heating capacity (7 Β°C)
- 5.20 kW
- Heating power input
- 1.37 kW
- EER, full load (tested)
- 3.49
- COP, full load (tested)
- 3.90
- Rated AEER
- 3.25
- Rated ACOP
- 3.78
- Standby power (PIA)
- 1.8 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- 54 dB(A)
- Outdoor sound power
- 64.2 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Rinnai HONRP50B zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 252 | 563 |
| Coldresidential | residential | 4.0 | 2.0 | 222 | 1,795 |
| Mixedcommercial | commercial | β | β | 439 | 291 |
| Mixedresidential | residential | 3.5 | 2.5 | 360 | 658 |
| Hotcommercial | commercial | β | β | 1,241 | 59 |
| Hotresidential | residential | 4.0 | 3.0 | 1,063 | 93 |
Part-load test points (23 values)
- c__t1_min_cap_power_rated
- 351 W
- h__h1_min_cap_power_rated
- 275 W
- h__h2_ext_cap_power_rated
- 1716 W
- c__t1_half_cap_power_rated
- 507 W
- c__t1_have_min_cap_results
- Yes
- h__h1_half_cap_power_rated
- 489 W
- h__h1_have_min_cap_results
- Yes
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h1_min_cap_heat_cap_rated
- 1334 W
- h__h2_ext_cap_heat_cap_rated
- 4820 W
- h__h1_half_cap_heat_cap_rated
- 2604 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_min_cap_power_rated
- 210.5 W
- c__t1_min_cap_cooling_cap_rated
- 1464 W
- c__low_temp_half_cap_power_rated
- 388 W
- c__t1_half_cap_cooling_cap_rated
- 2414.3 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_min_cap_cooling_cap_rated
- 1557 W
- c__low_temp_half_cap_cooling_cap_rated
- 2612 W
New Zealand E3 registration details
- Registration number
- ZAC0800
- GEMS registration id
- 164537
- Status
- approved, available (self-reported)
- Registration expires
- n/a (NZ registration)
- Registered for sale in
- New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] (Air Conditioners up to 65kW) EE Regulations 2020 Schedule 2A
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 9