c/kWh
Energy rating (cooling)
2
Heating: 1
Annual electricity use
24,476 kWh
3,133 cooling + 21,343 heating
Estimated running cost
$8,077 / year
$673 / month Β· $80,771 over 10 years
Capacity
43.3 kW cooling
44.4 kW heating

545% more electricity than the median of 13 comparable 40 kW reverse cycle ducted packaged registrations (3,797 kWh a year) in the cold zone. Uses less than 31% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 5% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Temperzone OPA450RLTFPQ running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 24,476$8,077$80,771
Mixed zone 13,416$4,427$44,273
Hot zone 15,748$5,197$51,968

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 43.3 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
APAC P040AHR3SA-RTT40.3 kW heating43 kW cooling3,057 kWh/yr2$1,009
APAC P040AHR3SA-LTT40.3 kW heating43 kW cooling3,057 kWh/yr2$1,009
Actron Air PCG400L39.5 kW heating39.2 kW cooling3,697 kWh/yr1$1,220
Actron Air PCG400R39.5 kW heating39.2 kW cooling3,697 kWh/yr1$1,220
Caa VPA045R3AC49.4 kW heating46.1 kW cooling3,718 kWh/yr1.5$1,227

Heat pumps similar to the Temperzone OPA450RLTFPQ

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
AIRSTAGE RAQ/K/WP/* 11843.6 kW heating43.3 kW cooling25,680 kWh/yr1$8,474
AIRSTAGE RAQ/K/WP/ECO/11843.6 kW heating43.3 kW cooling25,680 kWh/yr1$8,474
APAC P045AHR3SA-RRR44.8 kW heating43.1 kW cooling3,536 kWh/yr1.5$1,167
APAC P045AHR3SA-44.8 kW heating43.1 kW cooling3,536 kWh/yr1.5$1,167
Daikin UAYQ150CY1A43.1 kW heating42.8 kW cooling24,646 kWh/yr1.5$8,133
Daikin UAYN470AFY1A44.1 kW heating45.8 kW cooling25,884 kWh/yr1$8,542

Other Temperzone models of similar capacity

ModelStarsEst. cost / yrCompare
Temperzone OPA465RKTBG-P41.1 kW heating43.9 kW cooling3,797 kWh/yr1.5$1,253
Temperzone OPA465RKTB41.3 kW heating42.5 kW cooling4,036 kWh/yr1$1,332

Compare OPA450RLTFPQ with another model

Temperzone OPA450RLTFPQ specifications

Type
Reverse cycle
Configuration
Packaged
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
43.31 kW
Cooling power input
14.49 kW
Rated heating capacity (7 Β°C)
44.43 kW
Heating power input
14.17 kW
EER, full load (tested)
2.99
COP, full load (tested)
3.14
Rated AEER
2.98
Rated ACOP
3.13
Standby power (PIA)
11.5 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Three phase
Indoor sound power
–
Outdoor sound power
–
Demand response (AS/NZS 4755)
Yes
Country of manufacture
New Zealand, Australia

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Temperzone OPA450RLTFPQ zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––6,0727,219
Coldresidential2.01.03,13321,343
Mixedcommercial––8,1543,965
Mixedresidential2.01.04,8818,535
Hotcommercial––18,704839
Hotresidential2.01.014,4231,325
Part-load test points (23 values)
c__t1_min_cap_power_rated
4480 W
h__h2_ext_cap_power_rated
16622 W
c__t1_half_cap_power_rated
6090 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
7490 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
42667 W
h__h1_half_cap_heat_cap_rated
23370 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
3470 W
c__t1_min_cap_cooling_cap_rated
12080 W
c__low_temp_full_cap_power_rated
13243.86 W
c__low_temp_half_cap_power_rated
5030 W
c__t1_half_cap_cooling_cap_rated
19600 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
12680 W
c__low_temp_full_cap_cooling_cap_rated
46644.869999999995 W
c__low_temp_half_cap_cooling_cap_rated
21370 W

New Zealand E3 registration details

Registration number
AAC6442
GEMS registration id
134619
Status
approved, available (self-reported)
Registration expires
20 February 2027
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 7

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.