c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
2,154 kWh
252 cooling + 1,902 heating
Estimated running cost
$711 / year
$59 / month Β· $7,108 over 10 years
Capacity
5 kW cooling
5.6 kW heating

About the same electricity as the median of 236 comparable 5 kW reverse cycle split system registrations (2,154 kWh a year) in the cold zone. Uses less than 48% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 74% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Toshiba running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 2,154$711$7,108
Mixed zone 1,092$360$3,604
Hot zone 1,235$408$4,076

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 5 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RXM46AVMA / FTXM46AVMA4.7 kW heating4.6 kW cooling1,543 kWh/yr4.5$509
Daikin RXM46WVMA / FTXM46WVMA4.7 kW heating4.6 kW cooling1,571 kWh/yr4.5$518
Gree GWH15AGDXD-K6DNA1A/O / GWH15AGDXD-K6DNA1A/I4.7 kW heating4.6 kW cooling1,835 kWh/yr4$606
Gree GWH15QDXE4.7 kW heating4.6 kW cooling1,839 kWh/yr3$607
Midea MFCA50VA-W/MFCA50VA-N5.2 kW heating5.2 kW cooling1,841 kWh/yr4.5$608

Heat pumps similar to the Toshiba

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Hisense HAWG18KR5.3 kW heating5 kW cooling1,993 kWh/yr4$658
Pioneer International HPR-18A25.1 kW heating5 kW cooling1,968 kWh/yr4$649
Kaden KS185.1 kW heating5 kW cooling2,008 kWh/yr3.5$663
Panasonic CU-HZ50DKR / CS-HZ50DKR6 kW heating5 kW cooling1,940 kWh/yr5.5$640
Actron Air WRC-050CS / WRE-050CS5 kW heating5 kW cooling1,936 kWh/yr5$639
Daikin RXM50AVMA / FTXM50AVMA6 kW heating5 kW cooling1,881 kWh/yr5.5$621
Daikin RXM50WVMA / FTXM50WVMA6 kW heating5 kW cooling1,903 kWh/yr5$628
Haier 1U50PFHRA / AS50PFHRA5.3 kW heating5 kW cooling1,973 kWh/yr4$651

Compare RAV-GP561ATP-A1/RAV-GM561KRTP-A with another model

Toshiba specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
5.00 kW
Cooling power input
1.26 kW
Rated heating capacity (7 Β°C)
5.60 kW
Heating power input
1.38 kW
EER, full load (tested)
3.90
COP, full load (tested)
4.18
Rated AEER
3.91
Rated ACOP
4.00
Standby power (PIA)
5.8 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
57 dB(A)
Outdoor sound power
63 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
Thailand

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Toshiba zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––475602
Coldresidential3.52.02521,902
Mixedcommercial––631311
Mixedresidential3.52.5395697
Hotcommercial––1,44470
Hotresidential4.03.51,127108
Part-load test points (18 values)
h__h2_ext_cap_power_rated
1250 W
c__t1_half_cap_power_rated
470 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
510 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
4500 W
h__h1_half_cap_heat_cap_rated
2800 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
380 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
2500 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
2650 W

New Zealand E3 registration details

Registration number
AAC8829
GEMS registration id
169057
Status
approved, available (self-reported)
Registration expires
5 May 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 9