New Zealand Β· costs in NZD
Reverse cycle split system air conditioner
Z Zentri ZDA-100INV-AU Heat Pump
Z Zentri ZDA-100INV-AU is a 10.5 kW reverse cycle ducted split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC9979).
- Energy rating (cooling)
- 3.5
- Heating: 2
- Annual electricity use
- 4,749 kWh
- 550 cooling + 4,199 heating
- Estimated running cost
- $1,567 / year
- $131 / month Β· $15,672 over 10 years
- Capacity
- 10.5 kW cooling
- 12.5 kW heating
About the same electricity as the median of 136 comparable 10 kW reverse cycle ducted split system registrations (4,758 kWh a year) in the cold zone. Uses less than 51% of them.
Across all 3,612 air conditioner registrations sold in Australia, it uses less than 41% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Z Zentri ZDA-100INV-AU running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 4,749 | $1,567 | $15,672 |
| Mixed zone | 2,401 | $792 | $7,923 |
| Hot zone | 2,697 | $890 | $8,900 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 10.5 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-100PZ4R8 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr | 3 | $1,199 | |
| Panasonic U-100PZ3R5 / S-1014PF3E9.5 kW heating9.5 kW cooling3,634 kWh/yr | 3 | $1,199 | |
| Brivis AONSR13B1/AINHU11B111.3 kW heating10.3 kW cooling3,713 kWh/yr | 5 | $1,225 | |
| Midea UCMI90OB/DUCMI90IB11 kW heating10.5 kW cooling4,207 kWh/yr | 4.5 | $1,388 | |
| Midea DUCMI105IHB/UCMI105OB11 kW heating10.5 kW cooling4,207 kWh/yr | 4.5 | $1,388 |
Heat pumps similar to the Z Zentri ZDA-100INV-AU
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Aurora AU-BS36HR-2A-O / AU-LCF36-2A-I11.5 kW heating10.5 kW cooling4,349 kWh/yr | 4.5 | $1,435 | |
| Actron Air LRC-100CS / LRE-100CS11.5 kW heating10.5 kW cooling4,311 kWh/yr | 4.5 | $1,423 | |
| Rinnai DONSR11B1/DINLR11B111.5 kW heating10.5 kW cooling4,404 kWh/yr | 4.5 | $1,453 | |
| Midea DUCMI105IB/UCMI105OB11 kW heating10.5 kW cooling4,207 kWh/yr | 4.5 | $1,388 | |
| Mdv C-UV-105N8-QC3W / CDV-105A6N8-QC3W11 kW heating10.5 kW cooling4,253 kWh/yr | 4.5 | $1,403 | |
| Mdv C-UV-105N8-QC3W / CDV-105HN8-QC3W11 kW heating10.5 kW cooling4,244 kWh/yr | 4.5 | $1,401 | |
| Rinnai DONSR11B1/DINLR11B111.5 kW heating10.5 kW cooling4,403 kWh/yr | 4.5 | $1,453 | |
| Midea UCMI90OB/DUCMI90IB11 kW heating10.5 kW cooling4,207 kWh/yr | 4.5 | $1,388 |
Compare ZDA-100INV-AU with another model
Z Zentri ZDA-100INV-AU specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Ducted
- Indoor unit
- β
- Rated cooling capacity (35 Β°C)
- 10.50 kW
- Cooling power input
- 2.48 kW
- Rated heating capacity (7 Β°C)
- 12.50 kW
- Heating power input
- 2.90 kW
- EER, full load (tested)
- 4.30
- COP, full load (tested)
- 4.37
- Rated AEER
- 4.19
- Rated ACOP
- 4.27
- Standby power (PIA)
- 8.3 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Single phase
- Indoor sound power
- β
- Outdoor sound power
- 69.9 dB(A)
- Demand response (AS/NZS 4755)
- Yes
- Country of manufacture
- China
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Z Zentri ZDA-100INV-AU zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,039 | 1,347 |
| Coldresidential | residential | 3.5 | 2.0 | 550 | 4,199 |
| Mixedcommercial | commercial | β | β | 1,390 | 698 |
| Mixedresidential | residential | 3.5 | 2.5 | 850 | 1,551 |
| Hotcommercial | commercial | β | β | 3,163 | 152 |
| Hotresidential | residential | 4.0 | 3.0 | 2,460 | 237 |
Part-load test points (18 values)
- h__h2_ext_cap_power_rated
- 4250 W
- c__t1_half_cap_power_rated
- 1160 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 1210 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 11800 W
- h__h1_half_cap_heat_cap_rated
- 6400 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_half_cap_power_rated
- 900 W
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 5400 W
- c__low_temp_have_half_cap_results
- Yes
- c__low_temp_half_cap_cooling_cap_rated
- 5500 W
New Zealand E3 registration details
- Registration number
- AAC9979
- GEMS registration id
- 178223
- Status
- approved, available (self-reported)
- Registration expires
- 24 March 2031
- Registered for sale in
- Australia, Fiji, New Zealand
- Family
- β
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.2:2012
- MEPS
- 2019
- Product class
- Class 11
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.