c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
6,615 kWh
751 cooling + 5,864 heating
Estimated running cost
$2,183 / year
$182 / month Β· $21,830 over 10 years
Capacity
14 kW cooling
16.5 kW heating

2% less electricity than the median of 124 comparable 14 kW reverse cycle ducted split system registrations (6,763 kWh a year) in the cold zone. Uses less than 65% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 27% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Z Zentri ZDA-140INV-AU running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 6,615$2,183$21,830
Mixed zone 3,395$1,120$11,204
Hot zone 3,805$1,256$12,557

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 14 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RZA160CV1 / FDYAN160AV118 kW heating15.5 kW cooling4,493 kWh/yr2$1,483
Panasonic U-125PZ4R8 / S-125PE4R12.5 kW heating12.5 kW cooling4,742 kWh/yr3$1,565
Panasonic U-125PZ4R8 / S-125PE4*12.5 kW heating12.5 kW cooling4,742 kWh/yr3$1,565
Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling4,776 kWh/yr4$1,576
Rinnai DONSR13B1/DINLR13B113 kW heating12.5 kW cooling4,830 kWh/yr4$1,594

Heat pumps similar to the Z Zentri ZDA-140INV-AU

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Midea DUCMI140IHB/UCMI140OB14.5 kW heating14 kW cooling5,596 kWh/yr4$1,847
Actron Air URC-140CS / LRE-140CS14.3 kW heating14 kW cooling5,513 kWh/yr4$1,819
Mdv C-UV-140N8-QC3W / CDV-140HFN8-QC3W14.5 kW heating14 kW cooling5,664 kWh/yr4$1,869
Actron Air URC-140DS / LRE-140DS15.5 kW heating14 kW cooling5,768 kWh/yr4$1,903
Mdv C-UV-140N8-QC3W / CDV-140A6N8-QC3W14.5 kW heating14 kW cooling5,607 kWh/yr3.5$1,850
Rinnai DONSR15B1/DINLR15B114.5 kW heating14 kW cooling5,618 kWh/yr4$1,854
Midea UCMI140OB/DUCMI140IHB14.5 kW heating14 kW cooling5,658 kWh/yr4$1,867
Kaden KDI48 / KDI4814 kW heating14 kW cooling5,394 kWh/yr4$1,780

Compare ZDA-140INV-AU with another model

Z Zentri ZDA-140INV-AU specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
14.00 kW
Cooling power input
3.85 kW
Rated heating capacity (7 Β°C)
16.50 kW
Heating power input
4.20 kW
EER, full load (tested)
3.50
COP, full load (tested)
4.01
Rated AEER
3.62
Rated ACOP
3.91
Standby power (PIA)
6.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
73.4 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Z Zentri ZDA-140INV-AU zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––1,4121,887
Coldresidential3.52.07515,864
Mixedcommercial––1,915991
Mixedresidential3.02.51,1852,210
Hotcommercial––4,453207
Hotresidential3.52.53,479326
Part-load test points (18 values)
h__h2_ext_cap_power_rated
5300 W
c__t1_half_cap_power_rated
1500 W
c__t1_have_min_cap_results
No
h__h1_half_cap_power_rated
1680 W
h__h1_have_min_cap_results
No
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h2_ext_cap_heat_cap_rated
15500 W
h__h1_half_cap_heat_cap_rated
8100 W
h__h2_is_capable_extended_load
Yes
c__low_temp_half_cap_power_rated
1160 W
c__low_temp_have_min_cap_results
No
c__t1_half_cap_cooling_cap_rated
7100 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_half_cap_cooling_cap_rated
7100 W

New Zealand E3 registration details

Registration number
AAC9982
GEMS registration id
178226
Status
approved, available (self-reported)
Registration expires
29 March 2031
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.