c/kWh
Energy rating (cooling)
5
Heating: 2.5
Annual electricity use
1,043 kWh
108 cooling + 935 heating
Estimated running cost
$344 / year
$29 / month Β· $3,442 over 10 years
Capacity
2.7 kW cooling
3.2 kW heating

3% less electricity than the median of 177 comparable 2.5 kW reverse cycle split system registrations (1,073 kWh a year) in the cold zone. Uses less than 53% of them.

Across all 3,611 air conditioner registrations sold in Australia, it uses less than 88% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Gree running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 1,043$344$3,442
Mixed zone 526$174$1,736
Hot zone 553$182$1,825

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 2.7 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Hitachi RAC-VJ25NHAE/RAI-VJ25RHAE3.5 kW heating2.5 kW cooling653 kWh/yr4$215
Midea MFEP26VA-W/MFEP26VA-N2.7 kW heating2.6 kW cooling776 kWh/yr6.5$256
Actron Air WRC-026DS / WRE-026DS2.7 kW heating2.6 kW cooling790 kWh/yr7$261
Midea MFEP26VB-W/MFEP26VB-N2.7 kW heating2.6 kW cooling790 kWh/yr7$261
Actron Air WRC-026CS / WRE-026CS2.8 kW heating2.6 kW cooling804 kWh/yr7$265

Heat pumps similar to the Gree

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Braemar ACHV25D1S/ASHV25D1S3 kW heating2.7 kW cooling1,276 kWh/yr3.5$421
Kinghome KWH27ATBXB-K6DNA2/O / KWH27ATBXB-K6DNA2/I3 kW heating2.7 kW cooling1,276 kWh/yr3.5$421
Tosot TWH09ATBXB-K6DNA1C/O / TWH09ATBXB-K6DNA3C/I3 kW heating2.7 kW cooling1,276 kWh/yr3.5$421
Comfee CASG-XG25/CASN-XG252.8 kW heating2.7 kW cooling956 kWh/yr5.5$315
Euromatic EUR-9000FX2.6 kW heating2.7 kW cooling1,311 kWh/yr2$433
Westinghouse WSD27HWC-E / WSD27HWC-I3.3 kW heating2.7 kW cooling1,015 kWh/yr6.5$335
Actron Air WRC-026CS / WRE-026CS2.8 kW heating2.6 kW cooling804 kWh/yr7$265
Midea MFAB-26WC/MFAB-26NC2.7 kW heating2.6 kW cooling805 kWh/yr6$266

Compare GWH09AVCXD-K6DNA1A/O / GWH09AVCXD-K6DNA1A/I with another model

Gree specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Non-ducted
Indoor unit
Wall hung
Rated cooling capacity (35 Β°C)
2.70 kW
Cooling power input
0.57 kW
Rated heating capacity (7 Β°C)
3.20 kW
Heating power input
0.71 kW
EER, full load (tested)
4.60
COP, full load (tested)
4.37
Rated AEER
4.67
Rated ACOP
4.48
Standby power (PIA)
1.2 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
54.6 dB(A)
Outdoor sound power
62.5 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Gree zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––171296
Coldresidential5.02.5108935
Mixedcommercial––247156
Mixedresidential5.03.0170356
Hotcommercial––61732
Hotresidential5.54.050251
Part-load test points (23 values)
c__t1_min_cap_power_rated
158 W
h__h1_min_cap_power_rated
178 W
h__h2_ext_cap_power_rated
1350 W
c__t1_half_cap_power_rated
232 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
282 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
1040 W
h__h2_ext_cap_heat_cap_rated
3850 W
h__h1_half_cap_heat_cap_rated
1600 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
113 W
c__t1_min_cap_cooling_cap_rated
790 W
c__low_temp_half_cap_power_rated
168 W
c__t1_half_cap_cooling_cap_rated
1350 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
950 W
c__low_temp_half_cap_cooling_cap_rated
1310 W

1 model numbers on 1 other registration. Variants registered separately can carry different star ratings and energy figures; check the registration number on the label.

ModelRegistrationStarskWh / yr
GWH09AVCXD-K6DNA1A/O / GWH09AVCXD-K6DNA1A/IAAC850651,043

New Zealand E3 registration details

Registration number
AAC8805
GEMS registration id
168965
Status
approved, available (self-reported)
Registration expires
23 April 2030
Registered for sale in
Australia, Fiji, New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
Test standard
AS/NZS 3823.1.1:2012
MEPS
2019
Product class
Class 8

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.